504522

17

Electrical Requirements . . .

(Electric Dryers)

(120/240 Volt, 60 Hertz, 3-Wire Installation)
(120/208 Volt, 60 Hertz, 3-Wire Installation)

NOTE: The wiring diagram is located inside the 
control hood.

Grounding And Wiring Instructions

• The dryer must be connected to a grounded metal, 

permanent wiring system; or an equipment-grounding 
conductor must be run with the circuit conductors and 
connected to the equipment-grounding terminal or lead 
on the dryer.

• The dryer has its own terminal block that must be 

connected to a separate branch, 60 Hertz, single phase 

circuit, AC (alternating current) circuit, fused at 30 
Amperes
 (the circuit must be fused on both sides of the 
line).  ELECTRICAL SERVICE FOR THE 
DRYER SHOULD BE OF MAXIMUM RATED 
VOLTAGE LISTED ON THE NAMEPLATE. DO 
NOT CONNECT DRYER TO 110, 115, OR 120 
VOLT CIRCUIT.
 Heating elements are available for 
field installation in dryers which are to be connected to 
electrical service of different voltage than that listed on 
nameplate, such as 208 Volt.

• If branch circuit to dryer is fifteen feet (4.50 m) or less 

in length, use U.L. (Underwriters Laboratories) listed 
No. 10 A.W.G. wire (copper wire only), or as required 
by local codes. If over fifteen feet (4.50 m), use U.L. 
(Underwriters Laboratories) listed No. 8 A.W.G. wire 
(copper wire only), or as required by local codes. Allow 
sufficient slack in wiring so dryer can be moved from 
its normal location when necessary. 

• The power cord (pigtail) connection between wall 

receptacle and dryer terminal block IS NOT supplied 
with dryer.
 Type of pigtail and gauge of wire must 
conform to local codes and with instructions mentioned 
on the following pages.

• The method of wiring the dryer is optional and subject 

to local code requirements. See examples below.

To reduce the risk of fire, electric shock or 
personal injury, all wiring and grounding 
MUST conform with the latest edition of the 
National Electrical Code ANSI/NFPA 70 or the 
Canadian Electrical Code, CSA C22.1, and 
such local regulations as might apply. It is 
the customer’s responsibility to have the 
wiring and fuses checked by a qualified 
electrician to make sure the laundry room 
has adequate electrical power to operate the 
dryer.

W035

WARNING

D003IE3A

POWER SUPPLY

POWER SUPPLY

3-WIRE GROUNDED NEUTRAL

120/240 VOLT, 60 HERTZ AC 1 PHASE

SERVICE ENTRANCE SWITCH BOX

(SEE NOTE BELOW)

NEUTRAL

 WIRE

NEUTRAL

 WIRE

METALLIC OR

NON-METALLIC

SHEATHED CABLE

(

COPPER WIRE

ONLY)

PIGTAIL

TO DRYER

(SEE NOTE BELOW)

NEUTRAL

L1

L2

PIGTAIL CONNECTION

L1

L2

DIRECT CONNECTION

NEUTRAL

WALL

RECEPTACLE

INTERMEDIATE

FUSE BOX

(MAY BE

OMITTED IF

SERVICE

ENTRANCE

BOX IS FUSED)

INTERMEDIATE
SHUT-OFF BOX

(MAY OR MAY 

NOT BE FUSED)

A typical

30-Amp

Three-wire

Receptacle

NEMA Type

10-30R

30 AMPERE FUSES OR

CIRCUIT BREAKER

TERMINAL BLOCK

IN DRYER

120 

±

 12

VAC

240 

±

 12

VAC

120 

±

 12

VAC

NOTE: The power cord (pigtail) is NOT supplied with the 
electric dryer. Type of pigtail and gauge of wire must conform 
to local codes and instructions. 

The method of wiring the dryer is optional and subject to local 
code requirements.

NOTE: Connect the dryer to the power supply with the 
MAXIMUM RATED VOLTAGE listed on the nameplate.

NOTE: Use 

COPPER WIRE

 only. 

    Shorter than 15' (4.5 m) use 10 A.W.G.
    Longer than 15' (4.5 m) use 8 A.W.G.

Summary of Contents for 504522R3

Page 1: ...Installation and Operation Dryer Metered and Nonmetered Electric and Gas Models Part No 504522R3 July 1998 NOTA El manual en espa ol aparece despu s del manual en ingl s D334IE1D...

Page 2: ......

Page 3: ...ELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier f...

Page 4: ...t Source Check 14 Reversing Door Procedure 15 Manufactured Mobile Home Installation 16 Electrical Requirements Electric Dryers 17 Electrical Connection 18 Three Wire Power Cord 18 Four Wire Power Cord...

Page 5: ...el 15 If not installed operated and maintained in accordance with the manufacturer s instructions or if there is damage to or mishandling of this product s components use of this product could expose...

Page 6: ...0 Failure to install maintain and or operate this machine according to the manufacturer s instructions may result in conditions which can produce bodily injury and or property damage IMPORTANT Solvent...

Page 7: ...mum drying performance we recommend that more clearance be allowed around the dryer than the clearances that are listed throughout this manual ELECTRIC MODELS D329IE3A 23 5 59 7 cm 36 91 4 cm 43 2 109...

Page 8: ...performance we recommend that more clearance be allowed around the dryer than the clearances that are listed throughout this manual ELECTRIC MODELS D331IE3A 23 5 59 7 cm 36 91 4 cm 43 2 109 7 cm 28 7...

Page 9: ...d DO NOT use the special bracket if a 1 4 turn lock is used Coin Drawer Security for additional security drill out the two pilot holes on each front side of the meter case to 1 4 or 5 16 inch 6 4 or 8...

Page 10: ...umber of coins in coin slide Push slide in and observe through service door opening in meter case The slide extension should be contacting the accumulator actuator arm and moving back with slide trave...

Page 11: ...AC single Phase electrical supply GAS DRYER Dryer needs a 120 Volt 60 Hertz polarized 3 slot effectively grounded receptacle NOTE For more detailed information refer to Section on Electrical Requireme...

Page 12: ...t Requirements DO NOT use plastic or thin foil flexible ducting Locate dryer so exhaust duct is as short as possible Be certain old ducts are cleaned before installing your new dryer Use 4 10 2 cm dia...

Page 13: ...moving the cap 3 Connect to gas supply pipe 4 Tighten all connections securely Turn on gas and check all pipe connections internal external for gas leaks with a non corrosive leak detection fluid 5 Fo...

Page 14: ...ing through neutral STRAIN RELIEF NUT TYPICAL THREE WIRE RECEPTACLE POWER CORD Three Wire STRAIN RELIEF D275IE0D Three Wire NUT TYPICAL FOUR WIRE RECEPTACLE POWER CORD Four Wire STRAIN RELIEF D006IE0A...

Page 15: ...m inside dryer drum Step 6 Plug in the Dryer Refer to Section on Electrical Requirements and connect the dryer to an electrical power source Step 7 Check Installation Refer to Installer Check on the b...

Page 16: ...tered Models Set FABRIC SELECTOR switch at NORMAL and turn timer knob to 50 Close the loading door and press the PUSH TO START button IN USE light will come on indicating start of cycle igniter will g...

Page 17: ...ner from door panel B A 3 D273PE1B 4 Rotate door panel 180 degrees as shown D276PE1B 5 Remove door strike from door liner and reinstall on opposite side D269PE1D 6 Insert liner under flange on bottom...

Page 18: ...to any other duct vent or chimney Dryer exhaust duct MUST NOT terminate under the mobile home For proper operation it is important that the dryer has an ample amount of outside make up air The free ar...

Page 19: ...ryer Type of pigtail and gauge of wire must conform to local codes and with instructions mentioned on the following pages The method of wiring the dryer is optional and subject to local code requireme...

Page 20: ...and labeled as suitable for use in a clothes dryer 3 Tighten these wire binding screws firmly IMPORTANT Failure to tighten these screws firmly may result in wire failure at the terminal block 4 Secur...

Page 21: ...LIEF NOT SUPPLIED WITH DRYER NEUTRAL TERMINAL ACCESS COVER GROUND WIRE L2 TERMINAL L1 TERMINAL TERMINAL BRACKET GROUND SCREW SLOTTED HEX HEAD SCREWS Shipped inside the dryer Dryer is shown with the ac...

Page 22: ...Attach the green ground wire from the four wire power cord to the terminal block mounting bracket using the hex head screw removed in Step 4 Tighten the screw firmly 8 Using the three wire binding 10...

Page 23: ...GROUND WIRE POWER CORD FOUR WIRE STRAIN RELIEF RED WIRES GROUND WIRE BLACK WIRE L2 TERMINAL RED WIRE SLOTTED HEX HEAD SCREWS Shipped inside the dryer or removed in Step 2 Dryer is shown with the acce...

Page 24: ...OPERATING DO NOT OVERLOAD CIRCUITS See illustration below To reduce the risk of fire electric shock or personal injury all wiring and grounding MUST conform with the latest edition of the National Ele...

Page 25: ...al codes and ordinances DO NOT modify the plug provided with the dryer if it will not fit the outlet have a proper outlet installed by a qualified electrician If the laundry room s electrical supply d...

Page 26: ...ing system at test pressures equal to or less than 1 2 psi 3 45 kPa NOTE When connecting to a gas line an equipment shutoff valve must be installed within 6 1 8 m of the dryer An 1 8 N P T pipe plug m...

Page 27: ...w o Closet Door SIDE VIEW A A C A D E B CENTERED AIR OPENINGS G 2 Openings Minimum FRONT VIEW Closet Door F F OUTER WALL OF ENCLOSURE 42 NOTE For new installations locate top of wall vent 42 inches ab...

Page 28: ...louvers If it is necessary to duct make up air to the dryer increase the area of the ductwork by 25 percent to compensate for any reduction in air movement In addition the make up air duct should ext...

Page 29: ...use of the burner housing Dryer is shipped from factory ready for rear exhaust no kits required Exhausting the dryer through sides or bottom can be accomplished by installing a DK1 Sales Accessory Dir...

Page 30: ...ryer airflow Proper dryer airflow can be evaluated by measuring the static pressure Static pressure in the dryer s exhaust duct should be no greater than that shown in the chart below Check with dryer...

Page 31: ...nstalling an exhaust system does not eliminate the necessity of cleaning the dryer lint filter before each load The dryer interior and the complete exhaust system should be cleaned periodically by a q...

Page 32: ...p air must be supplied to replace air exhausted from dryers NOTE Where the exhaust duct pierces the wall or ceiling an opening having a diameter of 4 inches 10 2 cm larger than the diameter of the exh...

Page 33: ...BOW No cap or screen 24 MIN 60 96 cm VERTICAL DUCT HORIZONTAL DUCT MAIN COLLECTOR DUCT MAIN COLLECTOR DUCT Number of Dryers Minimum Diameter of Horizontal Collector Duct Minimum Diameter of Vertical C...

Page 34: ...iency of the dryer The clothes will take longer to dry and energy will be wasted Motor Overload Protector The motor overload protector stops the motor and shuts the heat off automatically in the event...

Page 35: ...and clean exhaust duct every one to two years as required thereafter The weather hood should be checked frequently to make sure the dampers move freely dampers are not pushed in and that nothing has...

Page 36: ...Push the coin slide all the way in Press the PUSH TO START button Has the laundry room fuse blown or become loosened or is a circuit breaker OFF The dryer itself does NOT have an electrical fuse Has t...

Page 37: ...ws Part No 35528 7 While supporting lower access panel remove two screws from bottom edge Gently lower access panel to disengage guide lugs from bottom edge of front panel 8 Remove two screws holding...

Page 38: ...ter before each use Step 2 Load Laundry Load clothes loosely into dryer drum Add fabric softener sheet if desired Step 3 Close Loading Door Close loading door Dryer will not operate with the door open...

Page 39: ...ERED MODELS Rotate timer knob to desired time setting up to 60 minutes After IN USE light comes on indicating start of cycle press the PUSH TO START button Remove knits when slightly damp because over...

Page 40: ...dryer drum Step 1 Clean Lint Filter Clean lint filter before each use Step 2 Load Laundry Load clothes loosely into dryer drum Add fabric softener sheet if desired Step 3 Close Loading Door Close load...

Page 41: ...ning To Insert Card Insert card into opening Follow directions on display DO NOT REMOVE THE CARD UNTIL DISPLAY READS Remove Card Remove knits when slightly damp because overdyring may cause shrinkage...

Page 42: ...The status word DRYING goes off at the end of a heated cycle or when the COOL DOWN cycle begins DOOR OPEN DOOR OPEN is lit and flashes at one second intervals whenever the dryer door is open COOL DOWN...

Page 43: ...t P O Box 990 Ripon WI 54971 0990 Date Purchased Model Number Serial Number Dealer s Name Dealer s Address Phone Number Service Agency Service Agency Address Phone Number NOTE Record the above informa...

Page 44: ...42 504522 Notes...

Page 45: ...Instalaci n y operaci n Secadoras operadas con monedas y operadas sin monedas Modelos el ctricos y a gas No de pieza 504522R3 Julio 1998 D334IE1D...

Page 46: ...ng n aparato electrodom stico No toque ning n interruptor el ctrico no use ning n tel fono en el edificio Aseg rese de que todas las personas salgan de la habitaci n edificio o rea Llame de inmediato...

Page 47: ...de la fuente de calor 57 Procedimiento para invertir la posici n de cada puerta 59 Instalaci n en construcciones prefabricadas m viles 60 Requisitos el ctricos secadoras el ctricas 61 Conexi n el ctr...

Page 48: ...ra secar 13 Mantenga el rea alrededor de la abertura del escape de aire caliente y el rea adyacente libres de acumulaci n de pelusa polvo o tierra 14 Un t cnico calificado debe limpiar peri dicamente...

Page 49: ...r Si las seca en la secadora limpie el tambor de secado con un trapo h medo para eliminar todas las part culas de fibra de vidrio 26 SIEMPRE siga las instrucciones de cuidados a la ropa indicados por...

Page 50: ...ar su instalaci n y el servicio Para obtener el rendimiento m ximo de su unidad de secadoras le recomendamos que deje m s espacio libre alrededor de la unidad de secadoras que el que se especifica en...

Page 51: ...servicio Para obtener el rendimiento m ximo de su unidad de secadoras le recomendamos que deje m s espacio libre alrededor de la unidad de secadoras que el que se especifica en este manual MODELOS EL...

Page 52: ...la m nsula ni el soporte especial si utiliza el seguro de 1 4 de vuelta Seguridad del caj n para monedas Para obtener seguridad adicional perfore los dos orificios piloto a cada lado en la parte dela...

Page 53: ...o de la caja del medidor La extensi n del tragamonedas debe hacer contacto con el brazo actuador y regresar a su posici n de reposo junto con el tragamonedas Cuando se empuja el tragamonedas completam...

Page 54: ...240 120 208 Voltios y 60 Hertzios SECADORAS A GAS Cada secadora requiere un tomacorriente con conexi n a tierra polarizado de 3 ranuras 120 Voltios y 60 Hertzios NOTA Para obtener informaci n m s det...

Page 55: ...a unidad de secadoras de tal forma que sus conductos de escape sean lo m s cortos posible Aseg rese de limpiar los conductos que ya hayan estado en uso anteriormente antes de instalar la nueva unidad...

Page 56: ...tapas 3 Conecte cada l nea de suministro de gas 4 Apriete con firmeza todas las conexiones Abra el suministro de gas y revise todas las conexiones internas y externas con alg n fluido no corrosivo par...

Page 57: ...CABLES DE 3 CONDUCTORES CABLE 3 conductores PROTECTOR CONTRA TIRONES D275IS0A TUERCA DEL PROTECTOR CONTRA TIRONES TOMACORRIENTE T PICO PARA CABLES DE 4 CONDUCTORES CABLE 4 conductores PROTECTOR CONTR...

Page 58: ...as secadoras Paso 6 Conecte la secadora Consulte la secci n Requisitos el ctricos y conecte cada secadora a una fuente de energ a el ctrica Paso 7 Revise la instalaci n Consulte la secci n Revisi n de...

Page 59: ...T para que arranque la secadora Una vez que la secadora haya funcionado durante tres minutos el aire de escape y o su conducto de escape deben estar tibios Modelos para operar sin monedas Coloque el S...

Page 60: ...antes de que el gas se haya encendido Si esto sucede despu s de aproximadamente dos minutos el dispositivo de encendido intenta una vez m s encender el gas Todos los modelos Una vez que cualquiera de...

Page 61: ...dispositivo de cerradura del panel interior de la puerta y vuelva a instalarlo en el lado opuesto D276PS1A 5 Quite el dispositivo de cerradura del panel interior de la puerta y vuelva a instalarlo en...

Page 62: ...o chimenea El conducto de escape de la secadora NO DEBE terminar abajo de la casa m vil Para que la secadora funcione adecuadamente es importante que tenga suficiente aire de reemplazo que provenga de...

Page 63: ...lir con los c digos locales y con las instrucciones que aparecen en las siguientes p ginas El m todo de cableado de la secadora es opcional y est sujeto a las normas del c digo local Vea los ejemplos...

Page 64: ...ra 240 Voltios m nimo 30 Amperios y adecuado para usarse en secadoras de ropa 3 Apriete estos tornillos de sujeci n con firmeza IMPORTANTE Si no se aprietan estos tornillos con firmeza los conductores...

Page 65: ...A CONEXI N NEUTRAL CUBIERTA DE ACCESO CONDUCTOR DE CONEXI N A TIERRA CONEXI N L2 CONEXI N L1 TORNILLO DE CONEXI N A TIERRA DE LA M NSULA DEL BLOQUE DE CONEXIONES TORNILLOS DE CABEZA HEXAGONAL ACANALAD...

Page 66: ...contra tirones desde el interior del gabinete y apriete con firmeza 7 Una el cable verde de conexi n a tierra del cable de corriente de 4 conductores a la m nsula de montaje del bloque de conexiones...

Page 67: ...E DE CORRIENTE CUATRO CONDUCTORES PROTECTOR CONTRA TIRONES CONDUCTORES ROJOS CONDUCTOR DE CONEXI N A TIERRA CONDUCTOR NEGRO CONEXI N L2 CONDUCTOR ROJO TORNILLOS DE CABEZA HEXAGONAL ACANALADA Se env an...

Page 68: ...guiente ilustraci n Para reducir el riesgo de causar un incendio una descarga el ctrica o de sufrir lesiones personales todo el cableado y las conexiones a tierra DEBEN cumplir con la ltima edici n de...

Page 69: ...e acuerdo a las normas y los reglamentos locales NO modifique la clavija que se entrega con la secadora si no la puede conectar en el tomacorriente haga que un electricista calificado instale un tomac...

Page 70: ...a 1 2 psi NOTA Al conectar a una l nea de gas es necesario instalar una v lvula de cierre al equipo a menos de 1 8 m 6 pies de la secadora Es necesario instalar un tap n de tuber a NPT de 1 8 plg como...

Page 71: ...CIRCULACI N DE AIRE 2 aberturas como m nimo VISTA DELANTERA puerta del armario F F PARED EXTERIOR DEL NICHO 42 NOTA En instalaciones nuevas coloque la parte superior de la abertura para el conducto de...

Page 72: ...adoras DEBEN tener una salida de escape al exterior W116S Este aparato electrodom stico a gas contiene o produce sustancias qu micas que pueden causar la muerte o enfermedades serias y que el Estado d...

Page 73: ...Aseg rese de limpiar los conductos viejos antes de instalar su secadora La longitud m xima recomendada del sistema de escape para obtener los mejores resultados de secado es la que se indica a contin...

Page 74: ...e ah en adelante La campana de protecci n contra la intemperie debe ser revisada con frecuencia para asegurarse de que los reguladores de tiro persianas se muevan sin restricciones que los reguladores...

Page 75: ...nducto de escape aproximadamente a 61 cm 2 pies de la secadora vea la siguiente ilustraci n IMPORTANTE NO bloquee el flujo de aire en la parte inferior del panel delantero de la secadora con ropa alfo...

Page 76: ...ape no se elimina la necesidad de limpiar el filtro de pelusa de las secadoras antes de poner cada carga en ellas El interior de las secadoras y todo el sistema de escape debe ser limpiado peri dicame...

Page 77: ...eemplazo para reemplazar el aire consumido por la combusti n de las secadoras NOTA El lugar en que el conducto de escape entra en la pared o el techo debe hacerse un orifico 10 2 cm 4 plg m s grande q...

Page 78: ...PRETIL TECHO CODO DE COMBA DE 180 sin tapa ni malla 60 96 cm M N 24 plg CONDUCTO VERTICAL CONDUCTO HORIZONTAL CONDUCTO COLECTOR PRINCIPAL CONDUCTO COLECTOR PRINCIPAL N mero de secadoras Di metro m ni...

Page 79: ...tarda m s en secar y se desperdicia mucha energ a Protector de sobrecarga del motor El protector de sobrecarga del motor detiene el funcionamiento del motor y cierra la fuente de calor autom ticamente...

Page 80: ...da uno o dos a os seg n se requiera de ah en adelante Las campanas contra la intemperie deben ser revisadas con frecuencia para asegurarse de que los reguladores de tiro persianas se muevan sin restri...

Page 81: ...tro Oprima el bot n OPRIMIR PARA ARRANCAR PUSH TO START Se ha quemado o aflojado alg n fusible o est apagado el interruptor de circuito La secadora en s NO cuenta con un fusible el ctrico Se ha activa...

Page 82: ...panel de acceso inferior saque dos tornillos de la orilla inferior Baje el panel de acceso con cuidado para zafar las gu as de la orilla inferior del panel delantero 8 Saque dos tornillos que sostien...

Page 83: ...Meta la ropa Meta la ropa en el tambor de la secadora Meta tambi n una hoja de suavizador si as lo desea Paso 3 Cierre la puerta del tambor Cierre la puerta del tambor La secadora no funciona con la...

Page 84: ...tiempo deseado hasta 60 minutos Una vez que la luz indicadora de foncionamiento IN USE se ilumine lo que indica el inicio de ciclo oprima el bot n de OPRIMIR PARA ARRANCAR PUSH TO START Saque las pre...

Page 85: ...etergente y agua y una tela h meda para eliminar el polvo que se acumula durante el env o en el interior del tambor de la secadora Paso 1 Limpie el filtro de pelusa Limpie el filtro de pelusa antes de...

Page 86: ...l precio en el indicador digital Si la caracter stica de tiempo adicional est activada es posible adquirir tiempo adicional de secado al principio del ciclo o durante el periodo de secado Para introdu...

Page 87: ...estado DRYING SECANDO se apaga al final del ciclo de calentamiento o cuando comienza el ciclo de COOL DOWN ENFRIAMIENTO DOOR OPEN PUERTA ABIERTA Esta luz se ilumina y se enciende y se apaga a interva...

Page 88: ...1 0990 U S A Fecha de compra N mero de modelo N mero de serie Nombre del distribuidor Direcci n del distribuidor Tel fono Agencia de servicio Direcci n de la agencia de servicio Tel fono NOTA Registre...

Page 89: ......

Page 90: ......

Page 91: ......

Page 92: ...ct Each Dryer Exhaust System Conecte el sistema de escape de la secadora CHECK REVISADO Connect Gas Supply Pipe Check for Gas Leaks Conecte la l nea de suministro de gas a cada una de las secadoras Re...

Reviews: