background image

LUBMATIC

 Mini DC Timer

ELECTRICAL OIL AND
LIQUID GREASE PUMP

INTRODUCTION AND USER MANUAL

VERSION 4.00 - 10.2018

Summary of Contents for LUBMATIC MINI Series

Page 1: ...LUBMATIC Mini DC Timer ELECTRICAL OIL AND LIQUID GREASE PUMP INTRODUCTION AND USER MANUAL VERSION 4 00 10 2018 ...

Page 2: ...ill be increased INTRODUCTION ABOUT MANUFACTURER With over 25 years experience of manufacturing Centralized Lubrication Systems ALLFETT is able to provide a wide professional approach to select the correct Centralized Lubrication System for industry and heavy machinery A highly accurate manufacturing process is involved in producing Centralized Lubrication Systems in order that systems meet the ve...

Page 3: ...connection information Control card description Control card panel description Control card programming instructions Rules to comply while using and warranty conditions Maintenance information Order information Warranty Warranty conditions PAGE 1 PAGE 2 PAGE 3 PAGE 4 PAGE 5 PAGE 6 PAGE 7 PAGE 8 PAGE 9 PAGE 10 PAGE 11 PAGE 12 13 PAGE 14 PAGE 15 PAGE 16 PAGE 17 ...

Page 4: ...ramming and also system monitoring can be done by integrated control unit Pumps are pruduced to be used in centralized lubrication systems only with time intervals It is not convenient to operate pumps more than 2 hours continuously Damages occur from this reason DISQUALIFIES THE WARANTY Single line fixed dose oil Single line dose adjustable oil Single line dose adjustable liquid grease Progressiv...

Page 5: ...ww allfett net PRODUCT DIMENSIONS Technical drawings below represents the LUBMATIC pump models which has 3 liters reservoir capacities Dimension unit is milimeter 200mm Assembly hole dimensions 162 290mm 152mm ...

Page 6: ...el without integrated control unit Optional specifications described seperately Electrical socket Outlet Reservoir Motor cover Filling filter Filling cover By pass Security relief valve Pump system Low level indicator Electrical coupling Mounting holes Low level indicator Reservoir lock Electronic control card ...

Page 7: ...ting time period can be programmed to electronic control card memory Stoping electrical motor of the pump couse by pass line to be open Lubricant inside main line is sended back to pump reservoir by by pass system Single line system distributors are now redy to operate for another lubrication cycle If necessary progressive distributors can be used with LUBMATIC pumps Detailed information about usi...

Page 8: ... if gets harder and loose fluidity at cold temperatures LUBMATIC pumps are designed to use with in centralized lubrication systems only It is not suitable to use LUBMATIC pump for lubricant tranfering or circulation purpose Filling filter must be checked after each filling Cleaning filter is important at regular time intervals Lubricant will be used in the system must certainly be clean and any fo...

Page 9: ...ket female part Electrical socket male part External alarm signal is placed to connectin number 2 If its needed to connect an external warning device signal must be connected to device externally All electrical connections and lines must be checked regularly for damage and to ensure that they are firmly in place Pumps have an electric driven motor Electrical lines must be connected properly as des...

Page 10: ...l voltage It is important taht the electrical connections must be done properly LUBMATIC pumps designed to work indoor applications Pump must not be exposed to external factors such as rain dust and dirt Control card panel Transformer is necessary if there is no 24 V DC electrical source Use minimum 5A current transformer CONTROL CARD SPECIFICATIONS Warnings Fuse broken Fault Alarm Waiting time pe...

Page 11: ... LED Indicates working period is on WARN Red LED Indicates alarm mode is on SERVICE This button is used to start programing and applying changes PROGRAM This screen shows all necessary information about programming ADDITIONAL CYCLE This button operates an additional lubrication cycle any time its pressed Control panel details of electronic control card are described below Before programming the co...

Page 12: ...cle button until desired number shown in flashing digit Press SERVICE button to save digit 7 After first digit saved second digit starts to flash ADDITIONAL CYCLE button changes the numbers shown in flashing digit Press Additional cycle button until desired number shown in flashing digit Press SERVICE button to save digit While integrated control card is on If ADDITIONAL CYCLE button pressed 2 sec...

Page 13: ...ng voltage to product DISQUALIFIES THE WARANTY All electrical connections and lines must be checked regularly for damage and to ensure that they are firmly in place 6 Pumps have an electric driven motor Electrical lines must be connected properly as described in ELECTRICAL CONNECTIONS section of this manual and applied only by qualified and instructed personel 5 Pump reservoir is made of transpare...

Page 14: ...d aids prohobited and DISQUALIFIES THE WARANTY Only maintenance may apply descibed in PAGE 14 15 ALLFETT Technical Service must be informed to any other possible troubles and necessary procedures must be performed 18 ALLFETT Mekanik ve Elektronik Sistemler SAN TIC LTD STI and ALLFETT Pazarlama ve Dis Ticaret LTD STI does not accept responsibility for damages described in items above on equipments ...

Page 15: ...m 5A current External control unit PLC etc may be in alarm mode due to low level signal from pump Lubricant inside reservoir may under low level line on sticker Fill reservoir with appropriate lubricant described in PAGE 7 in this manual External control unit may in waiting period Wait until programmed waiting period or operate a manual lubrication cycle a b c d e 2 Pump is working but not sending...

Page 16: ...PAGE 15 www allfett net LUBMATIC Mini Timer 24 V DC 1 5 Liters ORDER INFORMATION Ordering number Product name 10 24 TM 03 SALES ...

Page 17: ...ANTY PRODUCER COMPANY FAX TELEPHONE CENTRAL ADRESS NAME ALLFETT Mekanik ve Elektronik Sistemler San ve Tic Ltd Þti 0212 501 33 37 0212 501 32 01 PBX Yeni Eyup Bulvari Topcular Cad Set Ustu No 1 Demirkapý Rami Ýstanbul AUTHORISED PERSON SIGNATURE STAMP PRODUCT TYPE Electrical oil and liquid grease pump BRAND ALLFETT MODEL SERIAL NUMBER DELIVERY DATE PLACE WARRANTY 2 years REPAIR TIME LUBMATIC DC st...

Page 18: ...d expenses of any sort including labor the value of the parts replaced or any our charges The product will be replaced free of charge If the product permanently disfunctions due to repeating the same defect more than four times within the warranty period If the maximum period for repairing is exceeded If it is determined that the defect cannot be repaired by report written by the service or in the...

Page 19: ...and human health during use TRANSPORT AND STORAGE There are no restrictions on transportation by land air and sea In general products should be stored in a dry and dust free environment The storage temperatures are between 10 C and 40 C All products are packed with paper based support matarial to reduce damage Upon receiving the package please check the items for possible damage PAGE 18 www allfet...