Page
9
www.allfett.net
Cartridge replacing steps are explained by sections below. The most important point about replacing
the cartridge is, there must not be air gaps inside of cartridge place (Figure-6) on pump body. After old
cartridge removed, little amount grease remaining inside old cartridge should be used to fill cartridge place.
CARTRIDGE REPLACEMENT INSTRUCTIONS
REPLACEMENT STEPS
1.
Remove old cartridge from the pump by screwing counter clockwise.
2.
After old cartridge removed, little amount grease remaining inside old cartridge should be used to fill
cartridge place (
Figure - 1
).
GREASE MUST BE CLEAN WHILE ADDING TO CARTRIDGE PLACE
New cartridge will be installed without spring support.
3.
Piston inside new cartridge should be pushed by a long tool (such as hammer) untill 1 or 2 centimeters
long grease out from cartridge outlet (
Figure - 2
).
4.
New cartridge should be installed to pump body with grease on the outlet.
5.
Put new cartridge to cartridge place on pump then rotate clockwise until gets completely tight. Cartridge
thread must rotate properly and cartridge must stay vertical while rotating.
Grease should overflow between cartridge and pump body as seen in
Figure - 3.
6.
Spring support should be added on piston inside cartride as shown on
Figure - 4.
Please follow the instructions on next page to install spring support system.
Figure - 1
Push this way
At least 1-2cm long
grease should be out
Figure - 2
Cartridge place
Figure - 3
Grease should
overflow
Figure - 4
Piston
Spring
placed
up on
piston
Turn
Clockwise
Summary of Contents for ALL-6