162
Rockwell Automation Publication 750-UM006C-EN-P - March 2022
Chapter 5
Drive Maintenance
5. Use a
flathead screwdriver
to dislodge the circuit breaker from the DIN
rail.
6. Unpack and inspect the new circuit breaker.
7. Attach the circuit breaker to the DIN Rail.
8. Use a
flathead screwdriver
to attach the wires from
to the
terminals.
Torque screws to
12
lb•in
.
9. Set the end anchors in place and use a
flathead screwdriver
to tighten
their screws.
Torque screws to
4.4 lb•in
.
10. Follow instructions to
Attach the Front Cover on page 169
Replace the Drive HIM
(1HIM320)
Follow the procedure to
and follow the
Remove the Front Cover on page 148
. For information on how
to replace the HIM, see PowerFlex 20-HIM-A6 and 20-HIM-C6S HIM
(Human Interface Module) User Manual, publication
install the 20-HIM-CS6 HIM. After the HIM is replaced, follow the
instructions to
Attach the Front Cover on page 169
. and to
.
5
End Anchors
End Anchors
4 (x2)
Auxiliary Contact
Cat. No. 1489-AMRA3
Auxiliary Breakers
Cat. No. 1489-M2D040
Auxiliary Circuit Breaker
Cat. No. 140M-C2E-B25/
140MT-C3E-B25 and Auxiliary Contact
140M-C-AFA10/140MT-C-AFA10
Auxiliary Circuit Breaker
Cat. No. 1489-M2D040
Side View