Rockwell Automation Publication 750-UM006C-EN-P - March 2022
Chapter 4
Configure and Start Up the Drive
4. After the information is entered, click Apply to save changes.
Configure Digital Inputs
Use the Digital Input page to enter digital input values for the drive option
module. The appearance of this page for the PowerFlex 755 drives can vary
dependent upon the option module configuration. Use the Digital Input page
to assign specific actions to the inputs on the I/O option module that is located
in slot 7 of the drive. The drive is configured per the following table.
1. From the Module Properties dialog box, choose Digital Input.
2. Change the value of the inputs.
3. Click Apply to save changes.
TIP
Under axis properties, you may also elect to have the Logix controller read
the digital inputs as PLC I/O. See the electrical drawings for details regarding
the I/O wiring. It is recommended to not change digital inputs.
Digital Input
Description
1
DBRT – dynamic brake resistor thermostat
2
Electromechanical brake contactor auxiliary contact
3
Main circuit breaker and brake circuit breaker auxiliary contact input
4
P0 receptacle – Digital Input 2 and Digital Input 3
(20-750-2263C-1R2T I/O option module)
5
6
P1 receptacle – Digital Input 4 and Digital Input 5
(20-750-2263C-1R2T I/O option module)
7
8
Not wired