Publication 1747-6.5.5 - August 2000
H-2
Installing and Configuring the ControlNet Communications Driver
These settings depend on the devices installed on your computer. We
used the following addresses:
When deciding which addresses to use, remember that each card
in your computer must have a unique base memory address and a
unique base I/O space memory address. If another card in the
host computer is using one or both of the selected addresses, you
must change the card’s switch settings to an available address.
3.
Insert the card in a vacant 16- or 32-bit ISA/EISA expansion slot.
Configuring the 1784-KTCX15 Communications Driver
After installing the card in the computer, you must run
RSLinx
to
configure the driver.
1.
Start
RSLinx
.
2.
Select
Configure Drivers
from the
Communications
menu.
Front View
Side View
down (0)
up (1)
up (1)
down (0)
S3
240h shown
(adjust for your system)
Front of Switches
Base I/O Space Address
240
Base Memory Address
D000:000
TIP
Consult with your IT/PC support group to find
out if it is necessary to change any of your
computer’s memory address or IRQ settings.
Summary of Contents for SLC 500 DeviceNet
Page 1: ...SLC 500 DeviceNet Scanner Module 1747 SDN User Manual...
Page 4: ......
Page 52: ...Publication 1747 6 5 5 August 2000 3 16 Hardware Setup...
Page 68: ...Publication 1747 6 5 5 August 2000 4 16 Configuring the DeviceNet Network...
Page 86: ...Publication 1747 6 5 5 August 2000 5 18 Communicating with DeviceNet from Another Network...
Page 96: ...Publication 1747 6 5 5 August 2000 6 10 Creating and Running the Example Application Program...
Page 106: ...Publication 1747 6 5 5 August 2000 A 6 Data Map Example...
Page 118: ...Publication 1747 6 5 5 August 2000 E 4 Configuring SLC 5 05 Ethernet Communications...
Page 128: ...Publication 1747 6 5 5 August 2000 G 4 Installing and Configuring the DH Communications Driver...
Page 137: ......