Troubleshooting
7-5
Adapter Diagnostic Items are viewable with DriveExplorer (version 2.01
or higher), or DriveExecutive (version 1.01 or higher) software, or a
HIM (2.001 or higher).
Adapter Diagnostic Items
No.
Event
Description
1
Common Logic
Cmd
The current value of the Command Logic Command being
transmitted to the host.
2
Prod Logic Cmd
The current value of the Product-specific Logic Command being
transmitted to the host.
3
Reference
The current value ofthe product-specific Reference being transmitted
to the host.
4
Common Logic
Sts
The current value of the Product-Specific Logic Status being
received from the host.
5
Prod Logic Sts
The current value of the Product-Specific Status being received from
the host.
6
Feedback
The current value of the Product-Specific Feedback being received
from the host.
7
Datalink A1 In
The current value of Datalink A1 being transmitted to the host.
(Value of 0 if Datalink is not used).
8
Datalink A2 In
The current value of Datalink A2 being transmitted to the host.
(Value of 0 if Datalink is not used).
9
Datalink B1 In
The current value of Datalink B1 being transmitted to the host.
(Value of 0 if Datalink is not used).
10
Datalink B2 In
The current value of Datalink B2 being transmitted to the host.
(Value of 0 if Datalink is not used).
11
Datalink C1 In
The current value of Datalink C1 being transmitted to the host.
(Value of 0 if Datalink not used).
12
Datalink C2 In
The current value of Datalink C2 being transmitted to the host.
(Value of 0 if Datalink is not used).
13
Datalink D1 In
The current value of Datalink D1 being transmitted to the host.
(Value of 0 if Datalink is not used).
14
Datalink D2 In
The current value of Datalink D2 being transmitted to the host.
(Value of 0 if Datalink is not used).
15
Datalink A1 Out
The current value of Datalink A1 being received from the host.
16
Datalink A2 Out
The current value of Datalink A2 being received from the host.
17
Datalink B1 Out
The current value of Datalink B1 being received from the host.
18
Datalink B2 Out
The current value of Datalink B2 being received from the host.
19
Datalink C1 Out
The current value of Datalink C1 being received from the host.
20
Datalink C2 Out
The current value of Datalink C2 being received from the host.
21
Datalink D1 Out
The current value of Datalink D1 being received from the host.
22
Datalink D2 Out
The current value of Datalink D2 being received from the host.
23
DPI Rx Errors
The current value of the DPI Receive error counter.
24
DPI RX Err Max
The maximum value (since reset) of the DPI Receive error counter.
25
DPI Tx Errors
The current value of the DPI Transmit error counter
26
DPI Tx Err Max
The maximum value (since reset) of the DPI Transmit error counter.
27
Node Address SW The current value set on the Node Address Switches.
28
Boot Flash Count The number of times the Boot flash segment has been updated in
the field.
20COMM-UM003A-EN-P.book Page 5 Wednesday, November 7, 2001 3:46 PM
Summary of Contents for PowerFlex 20-comm-c FRN 1. Series
Page 6: ...iv Table of Contents Notes 20COMM UM003A EN P book Page iv Wednesday November 7 2001 3 46 PM...
Page 18: ...1 8 Getting Started 20COMM UM003A EN P book Page 8 Wednesday November 7 2001 3 46 PM...
Page 114: ...B 6 Adapter Parameters Notes 20COMM UM003A EN P book Page 6 Wednesday November 7 2001 3 46 PM...
Page 152: ...Glossary 6 Notes 20COMM UM003A EN P book Page 6 Wednesday November 7 2001 3 46 PM...
Page 154: ...20COMM UM003A EN P book Page 2 Wednesday November 7 2001 3 46 PM...