44
Rockwell Automation Publication 750-IN001O-EN-P - October 2014
Chapter 3
Lift and Mount the Drive
Install Floor Mount Drive
with Cabinet Options Bay
and Wiring Bay
Frame 9 drives configured with both the cabinet options bay and wiring bay ship
in two sections. The following procedure describes how to join the wiring bay to
the cabinet options bay.
1.
Remove external wrapping, bus bar cover, and locate joining hardware.
Joining hardware is shipped with the wiring bay.
Position the Drive Cabinets and Cabinet Options Bay
2.
Release the factory-assembled drive cabinets and cabinet options bay from
the shipping skid.
Description
Quantity
Description
Quantity
M8 x 16 mm Cabinet Joining Screw
20
M10 Nut with Washer
12
M10 x 45 mm Carriage Bolt
12
M6 x 40 mm bolts
4
Bus Bar Clamp Plate
12
M6 Flange Nuts
4
M8 x 16
13 mm
Drive Cabinets
Cabinet Options Bay
IP54, NEMA 12 Enclosure Rating Shown
Summary of Contents for PowerFlex 20-750-20COMM
Page 1: ...PowerFlex 750 Series AC Drives Catalog Numbers 20F 20G 21G Installation Instructions...
Page 6: ...6 Rockwell Automation Publication 750 IN001O EN P October 2014 Notes...
Page 10: ...10 Rockwell Automation Publication 750 IN001O EN P October 2014 Preface Notes...
Page 218: ...218 Rockwell Automation Publication 750 IN001O EN P October 2014 Chapter 4 Power Wiring Notes...
Page 301: ......