CIP Axis Attributes
Chapter 4
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
281
Bit
Exception Name
Description
3
Feedback Battery Loss
Battery powered Absolute Feedback device has failed to maintain absolute
position through a power cycle due to low battery level or disconnected battery
power.
4...15
-- Reserved --
The APR Fault exception names in the preceding tables have corresponding Logix
Designer APR Fault tag names. The naming conventions for the tag names are to
remove the spaces from the fault bit name and then append the "APRFault" suffix.
For example "Memory Write Error" becomes "MemoryWriteErrorAPRFault".
See also
Absolute Position Recovery Functionality
These configuration attributes control the action performed by the device as a
result of an exception condition. A unique exception action is defined for each
supported exception condition.
Axis Exception Action
Configuration Attributes