CIP Axis Attributes
Chapter 4
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
251
These are the inverter output related attributes associated with a Motion Control
Axis.
Output Frequency
Usage
Access
T Data
Type
Default
Min
Max
Semantics of Values
Required - F
Optional - C
Get/GSV
T REAL
-
-
-
Hertz
The Output Frequency attribute is the time averaged output frequency applied to
motor. Frequency value is in terms of electrical cycles.
Output Current
Usage
Access
T Data
Type
Default
Min
Max
Semantics of Values
Required - D
Get/GSV
T REAL
-
-
-
Amps (RMS)
The Output Current attribute is the total time averaged output current applied to
motor.
Output Voltage
Usage
Access
T Data
Type
Default
Min
Max
Semantics of Values
Required - D
Get/GSV
T REAL
-
-
-
Volts (RMS)
The Output Voltage attribute is the total time averaged phase-to-phase output
voltage applied to motor.
Output Power
Usage
Access
T Data
Type
Default
Min
Max
Semantics of Values
Required - D
Get/GSV
T REAL
-
-
-
Power Units
The Output Power attribute is the mechanical output power of the motor. This
value represents the product of applied motor torque/force and motor speed. If
the axis is configured for Frequency Control, the Velocity Feedback signal is
derived from the Velocity Reference signal.
Drive Output Attributes