Chapter 4
CIP Axis Attributes
234
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
These are the attributes that provide information about the associated hardware
capabilities of Motion Control Axis.
Inverter Rated Output Voltage
Usage
Access
T Data
Type
Default
Min
Max
Semantics of Values
Required - D
Get/GSV
REAL
-
-
-
Volts (RMS)
The Inverter Rated Output Voltage attribute is the drive inverter output voltage
rating. This value is hard coded in the device.
Inverter Rated Output Current
Usage
Access
T Data
Type
Default
Min
Max
Semantics of Values
Required - D
Get/GSV
REAL
-
-
-
Amps (RMS)
The Inverter Rated Output Current attribute is the drive inverter output current
rating. This value is hard coded in the device.
Inverter Rated Output Power
Usage
Access
T Data
Type
Default
Min
Max
Semantics of Values
Required - D
Get/GSV
REAL
-
-
-
Kilowatts
The Inverter Rated Output Power attribute is the drive inverter output power
rating. This value is hard coded in the device.
Converter Rated Output Current
Usage
Access
T Data
Type
Default
Min
Max
Semantics of Values
Optional - BD
Get/GSV
REAL
-
-
-
Amps (RMS)
The Converter Rated Output Current attribute is the drive converter output
current rating. This value is determined by the motion axis from the associated
converter.
Converter Rated Output Power
Usage
Access
T Data
Type
Default
Min
Max
Semantics of Values
Optional - BD
Get/GSV
REAL
-
-
-
Kilowatts
Axis Info Attributes