Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
297
Motion Control in PR Mode
Chapter 11
Figure 129 - Event Setting for Event Trigger
The following information describes the functions of ID386 (P5.098)
EventRisingEdgePRNumber.
Settings:
• X: PR triggered when EV1 is on
0: no action
1-D: execute PR#51…63
• Y: PR triggered when EV2 is on
0: no action
1-D: execute PR#51…63
X
PR triggered by EV1 rising-edge
Z
PR triggered by EV3 rising-edge
Y
PR triggered by EV2 rising-edge
U
PR triggered by EV4 rising-edge
Y
Z
U
X