Configure the Drive with KNX5100C Software
Chapter 7
Select a Motor and
Configure Feedback in
KNX5100C Software
There are three data sources available to configure the motor through the
Function List.
You can specify the motor data source and configure the related parameter value
via the motor pages according to data source and motor type.
Data Source
You can specify the data source where the motor parameters values originate.
The available data sources are:
• Motor NV: Motor parameter values are from the nonvolatile memory of a
motor. If the motor has an intelligent encoder, the value is used by the
drive to automatically identify the attached motors.
• Catalog number: Motor parameter values are from a catalog number.
Select the motor from the motor database embedded into the KNX5100C
software.
• Nameplate datasheet: Motor parameter values are from a motor nameplate
and data sheet. You must input this data manually.
TIP
The parameters displayed in the Motor Selection dialog box depend on the
data source and the type of motor selected.
IMPORTANT
When the nameplate data sheet is selected, the parameter field of
nameplate/data sheet parameter section of the Motor, Model, and
Motor Feedback pages are enabled, and you can input these values.
If a data source other than Nameplate data sheet is selected, the
parameter field of nameplate/data sheet parameter section of the
Motor, Model, and Motor Feedback pages are disabled and the motor
parameters values are read either from the intelligent encoder or the
KNX5100C motor database.