32
Rockwell Automation Publication 2097-UM002D-EN-P - April 2017
Chapter 2
Install the Kinetix 350 Drive System
Mount Your Kinetix 350 Drive
This procedure assumes that you have prepared your panel and understand
how to bond your system. For installation instructions regarding other
equipment and accessories, refer to the instructions that came with those
products.
Follow these steps to mount your Kinetix 350 drive.
1.
Lay out the position for the Kinetix 350 drive and accessories in the
enclosure.
on
for panel layout
recommendations. Mounting hole dimensions for the Kinetix 350 drive
are shown in Kinetix Servo Drives Specifications Technical Data,
publication number
.
2.
Attach the Kinetix 350 drive to the cabinet, first by using the upper
mounting slots of the drive and then the lower.
The recommended mounting hardware is M4 (#6-32) steel machine
screws that are torqued to 1.1 N•m (9.8 lb•in). Observe bonding
techniques as described in
3.
Tighten all mounting fasteners.
ATTENTION:
This drive contains electrostatic discharge (ESD) sensitive parts
and assemblies. You are required to follow static control precautions when
you install, test, service, or repair this assembly. If you do not follow ESD
control procedures, components can be damaged. If you are not familiar with
static control procedures, refer to Guarding Against Electrostatic Damage,
publication
, or any other applicable ESD Protection Handbook.
IMPORTANT
To improve the bond between the Kinetix 350 drive and subpanel,
construct your subpanel out of zinc plated (paint-free) steel.