64
Rockwell Automation Publication 1783-UM007I-EN-P - December 2017
Chapter 2
Get Started
If you start the switch from the SD card and then remove it while the switch is
running, the following conditions apply:
•
Device Manager is no longer be accessible.
•
Changes that are made by using the CLI or the Logix Designer
application take effect, but are not saved when the switch is restarted.
•
If you reinsert the SD card into the slot, changes are not saved to the card
unless new changes are made. Then the entire configuration is saved to
the card.
Synchronize the SD Card via Device Manager
To synchronize the SD card with the internal memory, use the Sync page. On
the Manual Sync tab, you can view the following:
•
Whether a card is present
•
Card status
•
If present, the source from which the switch was started
You can choose to synchronize the configuration or the software IOS from
either the SD card to the internal memory or from the internal memory to the
SD card.
The Auto Sync tab lets you configure default options for how Device Manager
prompts you after a configuration change or IOS update.
To display the Manual Sync and Auto Sync tabs, from the Admin menu,
choose Sync.
ATTENTION:
SD cards commonly have a physical read-only lock switch. If
this switch is engaged, the switch starts from the SD card successfully.
Changes that are made by using the CLI, AOP, or Device Manager take effect,
but are not saved when the switch is restarted.
Summary of Contents for armorstratix 5700
Page 10: ...10 Rockwell Automation Publication 1783 UM007I EN P December 2017 Table of Contents Notes ...
Page 12: ...12 Rockwell Automation Publication 1783 UM007I EN P December 2017 Preface Notes ...
Page 72: ...72 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 2 Get Started Notes ...
Page 396: ...396 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix A DataTypes Notes ...
Page 457: ......