440
Rockwell Automation Publication 1783-UM007I-EN-P - December 2017
Appendix D
Cables and Connectors
Connect to 10BASE-T- and 100BASE-TX-Compatible Devices
The auto-MDIX feature is enabled by default. Follow these cabling guidelines
when the auto-MDIX feature has been disabled.
When connecting the ports to 10BASE-T- and 100BASE-TX-compatible
devices, such as servers and routers, you can use a two or four twisted-pair,
straight-through cable that is wired for 10BASE-T and 100BASE-TX.
To identify a crossover cable, compare the two modular ends of the cable. Hold
the cable ends side-by-side, with the tab at the back. The color of the wire that
is connected to the pin on the outside of the left plug must differ in color from
the wire that is connected to the pin on the inside of the right plug.
and
show the cable schematics.
Figure 74 - Two Twisted-pair Straight-through Cable Schematics
Figure 75 - Four Twisted-pair Straight-through Cable Schematics
Switch
3 TD+
6 TD–
1 RD+
2 RD–
Router or Personal Computer
3 RD+
6 RD–
1 TD+
2 TD–
1 TPO+
2 TPO-
3 TP1+
6 TP1-
1 TP1+
Switch
Router or Personal Computer
2 TP1-
3 TPO+
6 TPO-
4 TP2+
5 TP2-
7 TP3+
8 TP3-
4 TP3+
5 TP3-
7 TP2+
8 TP2-
Summary of Contents for armorstratix 5700
Page 10: ...10 Rockwell Automation Publication 1783 UM007I EN P December 2017 Table of Contents Notes ...
Page 12: ...12 Rockwell Automation Publication 1783 UM007I EN P December 2017 Preface Notes ...
Page 72: ...72 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 2 Get Started Notes ...
Page 396: ...396 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix A DataTypes Notes ...
Page 457: ......