294
Rockwell Automation Publication 1783-UM007I-EN-P - December 2017
Chapter 4
Monitor the Switch
Off
Power is not present on the circuit, or the system is not powered up.
Solid green
Power output is good.
Flashing red
Power supply is installed, but power input is bad.
Solid red
Power output is bad.
Table 105 - Stratix 5410 System Status Indicators (Continued)
Indicator
Status
Description
Table 106 - Stratix 5410 Port Status Indicators
Mode
Status
Description
Status
In Status mode, the port status indicators show the connection and activity status of the port. Status mode is the default mode. You can choose Status mode via
the View pull-down menu in Device Manager. You can also choose Status mode by pressing the Disp. Mode button on the physical switch until all mode status
indicators on the switch turn off.
Off
No link is present on the port.
Solid green
Port link; no activity.
Flashing green and off
Link is active and healthy.
Alternating green and amber
There is a fault or error on the link.
Solid amber
The port is disabled.
Speed
In Speed mode, the port status indicators show the operating speed of the ports.
Ports 1…24
Off
The port is not operating.
Solid amber
The port is operating at 10 Mbps.
Solid green
The port is operating at 100 Mbps.
Flashing green
The port is operating at 1000 Mbps.
Ports 25…28
Off
The port is not operating.
Solid green
The port is operating at 1000 Mbps
Flashing green
The port is operating at 10 Gbps.
Duplex
In Duplex mode, the port status indicators show the Duplex mode (Full-duplex or Half-duplex) of the ports. The 10/100/1000 ports operate only in Full-duplex
mode.
Off
The port is not operating.
Solid amber
The port is operating in Half-duplex mode.
Solid green
The port is operating in Full-duplex mode.
PRP
In PRP mode, the port status indicators show the status of Parallel Redundancy Protocol (PRP). To configure PRP, see
.
Off
PRP is disabled or not in use on the port.
Solid green
PRP is configured and active on the port.
Solid amber
PRP is configured on the port and has a redundancy fault.
DLR—Not functional as of the current release.
Power
or
PoE
In Power or PoE mode, the port status indicators show the status of PoE.
The Power mode available via the View pull-down menu in Device Manager is the same as the PoE mode available via the Disp. Mode button on the physical
switch.
Off
PoE is not enabled on the port.
Solid green
PoE is enabled on the port and is functioning properly.
Alternating green and amber
PoE is enabled on the port, but power is disconnected or failing on this low priority port.
Flashing amber
PoE is enabled on the port, but power is disconnected or is failing on this high priority port.
Solid amber
PoE is enabled on the port, but has failures.
Summary of Contents for armorstratix 5700
Page 10: ...10 Rockwell Automation Publication 1783 UM007I EN P December 2017 Table of Contents Notes ...
Page 12: ...12 Rockwell Automation Publication 1783 UM007I EN P December 2017 Preface Notes ...
Page 72: ...72 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 2 Get Started Notes ...
Page 396: ...396 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix A DataTypes Notes ...
Page 457: ......