Configure Switch Features
Verify the GSD File
To verify that the GSD file for the switch matches the GSD file in the
controller configuration software, do the following.
1.
Establish a connection between the switch and the I/O controller.
2.
Start a CLI session.
3.
Enter the following command in the CLI and press Enter:
show profinet status
As shown in the following example, the GSD version line shows whether
the GSD file is a match or mismatch.
Monitor and Maintain PROFINET
Use the following commands in the CLI to display the PROFINET
configuration.
Command
Purpose
show profinet sessions
Displays the currently connected PROFINET sessions.
show profinet status
Displays the status of the PROFINET subsystem.
show lldp neighbor interface x/x detail
Displays information about the adjacent interface.