226
Rockwell Automation Publication 1783-UM007I-EN-P - December 2017
Chapter 3
Configure Switch Features
For Stratix 8000/8300 switches, in the navigation pane, click Advanced Port
Configuration.
Figure 30 - Advanced Port Configuration for Stratix 8000/8300 Switches
Table 86 - Advanced Port Configuration Fields for Stratix 8000/8300 Switches
Field
Description
Unit
Indicates where the port resides:
•
Base (for example, 1783-MS10T).
•
Expansion module (for example, 1783-MX08T).
Port
Indicates the port that is selected for configuration.
The port number includes the port type (Fa for Fast Ethernet and Gi for Gigabit Ethernet), the base or expansion module number (1, 2, or 3), and the
specific port number, such as in the following examples:
•
Gi1/1 is Gigabit Ethernet port 1 on the base.
•
Fa2/1 is Fast Ethernet port 1 on the first expansion module.
Smartport
Assign Smartports and VLANs via the Logix Designer Application on page 270
VLAN Type and ID
Authorized Device MAC ID
To authorize a specific MAC ID to communicate on the port, type the MAC ID of the device that is connected to the port. You can authorize only one
MAC ID to communicate on the port. If other MAC IDs communicate on the port, they are blocked. This feature must not be set for ports that are
connected to other switches or routers.
The MAC ID is also known as MAC ID, physical address, or hardware address. Each node on the network has a unique MAC ID. The MAC ID is six
hexadecimal numbers, such as 00-00-BC-22-A0-D8.
Summary of Contents for armorstratix 5700
Page 10: ...10 Rockwell Automation Publication 1783 UM007I EN P December 2017 Table of Contents Notes ...
Page 12: ...12 Rockwell Automation Publication 1783 UM007I EN P December 2017 Preface Notes ...
Page 72: ...72 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 2 Get Started Notes ...
Page 396: ...396 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix A DataTypes Notes ...
Page 457: ......