Rockwell Automation Publication 1783-UM007I-EN-P - December 2017
123
Configure Switch Features
Chapter 3
Beacon Interval
Type an interval for the supervisor to transmit beacon frames.
Valid values: 200…100,000 µs
The default interval is 400 µs.
Beacon Timeout
Type the amount of time ring nodes wait before timing out in the absence of received beacon messages.
Valid values: 400…500,000 µs
The default timeout is 1960 µs.
Ring Protocol VLAN ID
Reserved for future use.
Table 43 - Advanced Network Configuration Fields
Field
Description
Table 44 - Redundant Gateway Configuration Fields
Field
Description
Enable Redundant Gateway
Check the checkbox to enable the configuration of redundant gateways. The configuration fields are available only after you enable the feature.
Default: Disabled
Advertise Interval
Type the time interval for the gateway to transmit advertise messages.
Valid values: 200…100,000 µs
Default: 2000 µs
Advertise Timeout
Type the duration of time for nodes to wait before timing out in the absence of received advertise messages.
Valid values: 200…500,000 µs
Default: 5000 µs