30
Rockwell Automation Publication 6300B-UM002A-EN-P - October 2020
Chapter 6 Troubleshoot the System
Load the System Defaults
If the computer fails after you make changes in the set-up menus, load the
system default settings to correct the error. These default settings have been
selected to optimize computer performance.
Follow these steps to load the system defaults.
1.
Restart the computer as specified in
Restart the VersaView 6300B Wall
2. During POST, press F2 to access the UEFI set-up utility.
3. On the Main screen, press F9 to select the Optimized Default settings,
which are the system defaults.
4. Press F10 to save your changes and exit.
The change resets the system automatically.
Ship or Transport the
Computer
If you must ship the computer via common carrier or otherwise transport it to
another location for service or any other reason, you must first uninstall the
computer and place it in its original packing material.
IMPORTANT
An external display, keyboard, and mouse must be connected to perform
these steps.
ATTENTION:
Do not ship or transport the computer when it is installed in a
machine, panel, or rack. To avoid damage to the computer, you must uninstall the
computer and place it in its original packing material before you ship it.
Rockwell Automation is not responsible for damage to a computer that is shipped or
transported while installed in a machine, panel, or rack.