Rockwell Automation Publication 1756-UM010C-EN-P - June 2021
111
Appendix B Software Configuration Tags
C.Operations[1].kFactStruct.FreqAtKFactor[6]
Float
REAL
Freq[6] for KFactor [6]
C.Operations[1].kFactStruct.FreqAtKFactor[7]
Float
REAL
Freq[7] for KFactor [7]
C.Operations[1].kFactStruct.FreqAtKFactor[8]
Float
REAL
Freq[8] for KFactor [8]
C.Operations[1].kFactStruct.FreqAtKFactor[9]
Float
REAL
Freq[9] for KFactor [9]
C.Operations[1].kFactStruct.FreqAtKFactor[10]
Float
REAL
Freq[10] for KFactor [10]
C.Operations[1].kFactStruct.FreqAtKFactor[11]
Float
REAL
Freq[11] for KFactor [11]
C.Operations[1].kFactStruct.FreqAtKFactor[12]
Float
REAL
Freq[12] for KFactor [12]
C.OutputSetup[0].FaultMode
Decimal
SINT
Sets the state of output 0 when communications are lost with the owner-
controller in Fault Mode
0 = Continue operation
1 = Reset Output 0 to OFF when in Fault Mode
2 = Set Output 0 to ON when in Fault Mode
C.OutputSetup[0].ProgMode
Decimal
SINT
Sets the state of output 0 when communications are lost with the owner-
controller in Program Mode
0 = Continue operation
1 = Reset Output 0 to OFF when in Program Mode
2 = Set Output 0 to ON when in Program Mode
C.OutputSetup[0].DynamicError
Decimal
SINT
Sets the state of output 0 when a dynamic error occurs
0 = Continue operation
1 = Reset Output 0 to OFF on Error
2 = Set Output 0 to ON on Error
C.OutputSetup[0].TriggerOn
Decimal
SINT
Sets when output 0 energizes
0 = No Action
1 = Frequency
2 = Acceleration
3 = Full Flow State
4 = Trickle Flow State
5 = Prover Run State
6 = Prover Range State
C.OutputSetup[0].TieToCounter
Ties a channel to output 0
0 = No connection
1 = Connect Channel0 to Output0
2 = Connect Channel1 to Ouput0
C.OutputSetup[1].FaultMode
Decimal
SINT
Sets the state of output 1 when communications are lost with the owner-
controller in Fault Mode
0 = Continue operation
1 = Reset Output 0 to OFF when in Fault Mode
2 = Set Output 0 to ON when in Fault Mode
C.OutputSetup[1].ProgMode
Decimal
SINT
Sets the state of output 1 when communications are lost with the owner-
controller in Program Mode
0 = Continue operation
1 = Reset Output 0 to OFF when in Program Mode
2 = Set Output 0 to ON when in Program Mode
C.OutputSetup[1].DynamicError
Decimal
SINT
Sets the state of output 1 when a dynamic error occurs
0 = Continue operation
1 = Reset Output 0 to OFF on Error
2 = Set Output 0 to ON on Error
C.OutputSetup[1].TriggerOn
Decimal
SINT
Sets when output 1 energizes
0 = No Action
1 = Frequency
2 = Acceleration
3 = Full Flow State
4 = Trickle Flow State
5 = Prover Run State
6 = Prover Range State
C.OutputSetup[1].TieToCounter
Ties a channel to output 1
0 = No connection
1 = Connect Channel0 to Output 1
2 = Connect Channel1 to Output 1
(1) Additional Digital Filter options are now defined for Major Rev 3 and later in
Table 14 - Configurable Flowmeter Module Configuration Tags
Name
Style
Data Type
Definition