Rockwell Automation Publication 1734-UM001E-EN-P - July 2013
170
Default Data Maps
1734-OA2 Output Module
Message Size: 1 Byte
1734-OA4 Output Module
Message Size: 1 Byte
1734-OB2E, 1734-OB2 Electronically Protected Output Module
Message Size: 1 Byte
Message Size: 1 Byte
1734-OB4E, 1734-OB4 Electronically Protected Output Module
Message Size: 1 Byte
7
6
5
4
3
2
1
0
Produces (scanner Rx)
No produced data
Consumes (scanner Tx)
Not used
Ch1
Ch0
Channel state
Where: 0 = off, 1 = on
7
6
5
4
3
2
1
0
Produces (scanner Rx)
No produced data
Consumes (scanner Tx)
Not used
Ch 3
Ch 2
Ch1
Ch0
Channel state
Where: 0 = Off, 1 = On
7
6
5
4
3
2
1
0
Produces (scanner Rx)
Not used
Ch1
Ch0
Channel status
(1734-OB2E only)
Where: 0 = no error 1 = error
7
6
5
4
3
2
1
0
Consumes (scanner Tx)
Not used
Ch1
Ch0
Channel
state
Where: 0 = off 1 = on
7
6
5
4
3
2
1
0
Produces (scanner Rx)
Not used
Ch3
Ch2
Ch1
Ch0
Channel status (1734-
OB4E only)
Where: 0 = no error 1 = error
Summary of Contents for 1734-OB2
Page 4: ...Publication 1734 UM001E EN P July 2013 iv Summary of Changes Notes...
Page 16: ...Rockwell Automation Publication 1734 UM001E EN P July 2013 xxiv Notes...
Page 22: ...Rockwell Automation Publication 1734 UM001E EN P July 2013 6 About the Modules Notes...
Page 116: ...Rockwell Automation Publication 1734 UM001E EN P July 2013 118 POINT I O Module Data Notes...
Page 168: ...Rockwell Automation Publication 1734 UM001E EN P July 2013 176 Default Data Maps Notes...
Page 172: ...Rockwell Automation Publication 1734 UM001E EN P July 2013 180 Mounting Dimensions Notes...