POINT I/O Family

Overview

The POINT I/O family has modular I/O modules that are ideal for 
applications where flexibility and low-cost of ownership are key for successful 
control system design and operation. As a key element in the Rockwell 
Automation Integrated Architecture, its comprehensive diagnostics and 
configurable features allow the product to be easily applied to any automation 
system and reduce engineering costs through standardization. It can be used in 
remote device panels, local control panels, and can be accessed from many 
locations including the Internet. This product has just-what-you-need 
granularity in 1 to 8 points to reduce system cost and size. 

Available features include Channel Level Diagnostics for quick 
troubleshooting, multiple termination options and flexibility to save money, 
cabinet space and commissioning/troubleshooting time, the ability to 
mix/match Safety I/O on the same bus, and available DeviceLogix for local 
control, fast response time. Self-Configuring modules are also available to 
reduce/simplify your design and your inventory.

Summary of Contents for 1734-8CFG

Page 1: ...engineering costs through standardization It can be used in remote device panels local control panels and can be accessed from many locations including the Internet This product has just what you need...

Page 2: ...ons and system power for the backplane Power distribution modules provide the expandability of the POINT I O system and the flexibility to mix a variety of signal types 1734 POINT I O modules offer 1...

Page 3: ...indicator and electronic Channel level alarm and annunciation electronic Channel level open wire detection with electronic feedback Channel level short circuit detection with electronic feedback Param...

Page 4: ...electronic fusing isolated inputs outputs and unique configurable features 3 Select a wiring base assembly Choose the appropriate wiring base assembly the appropriate wiring base assembly Single piec...

Page 5: ...CE C Tick c UL us 1734 DC Configurable Input Output Modules Technical Specifications 1734 8CFG 1734 8CFGDLX with DeviceLogix Number of inputs iutputs 8 8 Voltage on state input nom Voltage on state in...

Page 6: ...tput Modules Environmental Specifications Attribute Value Operating temperature 20 55 C 4 131 F Nonoperating temperature 40 85 C 40 185 F Relative humidity 5 95 noncondensing Operating shock 30 g Nono...

Page 7: ...ler an EtherNet IP network that is local to that controller Power Supply Distance Rating Place modules to the right of the power supply Each 1734 I O module can be placed in any of the slots right of...

Page 8: ...x 1734 PDN on DeviceNet network 1300 mA Up to 17 Expansion power supply not allowed Not to exceed scanner capacity 1734 ADN X on DeviceNet network 1000 mA Up to 13 63 Not to exceed scanner capacity 17...

Page 9: ...734 IB8S 1734 OB8S and 1734 IE4S modules ensure that there is 2 in of clearance space above the POINT rail Allow a 25 4 mm 1 0 in air gap all around 133 4 mm 5 25 in 1734 PDN H x W x L 7 62 x 25 4 x 1...

Page 10: ...62 x 54 9 x 133 4 mm 3 00 x 2 16 x 5 25 in Allow a 25 4 mm 1 0 in air gap all around 1734 EP24DC or 1734 FPD H x W x L 7 62 x 25 4 x 133 4 mm 3 00 x 1 00 x 5 25 in 1734 TB or 1734 TBS with I O H x W...

Page 11: ...I O One piece Terminal Bases Installation Instructions publication 1734 IN028 1734 TBCJC Cold Junction Compensation Wiring Base Assembly Installation Instructions publication 1734 IN583 Power Units 1...

Reviews: