68
Rockwell Automation Publication 1791ES-UM001G-EN-P - November 2016
Chapter 4
Wiring Examples
Figure 24 - Two-hand Monitor
This example shows wiring and controller configuration when using the
Guard I/O™ module. If used in combination with the programs of a safety
controller, the wiring is Category 4 in accordance with ISO 13849-1:2008
wiring requirements.
In +
In -
FE
I0
I1
T0
T1
I2
I3
T2
T3M
S12
E1
S11
1
5
2
3
1
5
2
3
S12
S11
4
4
4
3
2
1
E1
1791ES Modules
1 - Test Output 1
2 - Input 1
3 - Input Common
4 - Input 0
5 - Test Output 0
1 - Output Power
2 - Input Power
3 - Input Common
4 - Output Common
1732ES Modules
1 - Test Output 3
2 - Input 3
3 - Input Common
4 - Input 2
5 - Test Output 2
Controller Configuration
Parameter Name
Configuration Setting
Safety Input 0
Safety Input 0 Channel Mode
Test Pulse from Test Output
Safety Input 0 Test Source
Test Output 0
Dual Channel Safety Input 0/1 Mode
Dual Channel Complementary
Dual Channel Safety Input 0/1 Discrepancy Time
100 ms (application dependent)
Safety Input 1
Safety Input 1 Channel Mode
Test Pulse from Test Output
Safety Input 1 Test Source
Test Output 1
Safety Input 2
Safety Input 2 Channel Mode
Test Pulse from Test Output
Safety Input 2 Test Source
Test Output 0
Dual Channel Safety Input 2/3 Mode
Dual Channel Complementary
Dual Channel Safety Input 2/3 Discrepancy Time
100 ms (application dependent)
Safety Input 3
Safety Input 3 Channel Mode
Test Pulse from Test Output
Safety Input 3 Test Source
Test Output 1
Test Output 0
Test Output 0 Mode
Pulse Test Output
Test Output 1
Test Output 1 Mode
Pulse Test Output