Publication 0160-5.18 - June 2003
B-28
DeviceNet Information
Class Code 0x04 —
Assembly Objects (Continued)
Instance Data Format: Input Assemblies (Continued)
➀
1 = forward, 0 = reverse
➃
0 = 0 Hz, 32767 = Maximum Frequency
The following table indicates the I/O Assembly Data Attribute
mapping for Input Assemblies.
Instance 105: Allen-Bradley Drive Input Assembly with Parameters
160 SSC parameter values are used to form the Output_Data structure for this assembly. Parameters 111 and 112 contain numbers of the display
parameter values that form this assembly. A value of 0 in either parameter 111 or 112 means end of assembly. For example, a value of 0 in parameter 112
means that the assembly will only be six bytes long, with parameter 111 containing the parameter number of the parameter whose value is placed in word
3 of the assembly.
Word
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1
0
Fault
N/A
Decel
Accel
Rot Dir
➀
Cmd Dir
➀
Running
Enabled
1
Freq Source
➂
Freq Source
➂
Freq Source
➂
Freq Source
➂
Local
➁
Local
➁
Local
➁
At Speed
2
2
Actual Speed Scale 0-32767
➃
3
Actual Speed Scale 0-32767
➃
3
4
Value of parameter pointed to by Parameter Number 111 (Low Byte)
5
Value of parameter pointed to by Parameter Number 111 (High Byte)
4
6
Value of parameter pointed to by Parameter Number 112 (Low Byte)
7
Value of parameter pointed to by Parameter Number 112 (High Byte)
➁
Local
➂
Frequency Source
Bit
11
Bit
10
Bit
9
Definition
Bit
15
Bit
14
Bit
13
Bit
12
Definition
0
0
0
TB3 Control
0
0
0
0
Preset 0
0
0
1
Network Control
0
0
0
1
Preset 1
0
0
1
0
Preset 2
0
0
1
1
Preset 3
0
1
0
0
Preset 4
0
1
0
1
Preset 5
0
1
1
0
Preset 6
0
1
1
1
Preset 7
1
0
0
0
TB3
1
0
0
1
Network
1
0
1
0
Not defined
1
1
1
1
Not defined
Data Component Name
Class
Instance
Number
Attribute
Name
Number
Name
Number
Faulted
Supervisor
29hex
1
Faulted
9
Running 1 (Fwd)
Supervisor
29hex
1
RunningFwd
7
Running 2 (Rev)
Supervisor
29hex
1
RunningRev
8
Ready
Supervisor
29hex
1
Ready
9
CtrlFromNet
Supervisor
29hex
1
CtrlFromNet
15
CtrlFromNet
AC Drive
2Ahex
1
RefFromNet
29
At Reference
AC Drive
2Ahex
1
AtReference
3
Speed Actual
AC Drive
B3hex
1
SpeedActual
7
Summary of Contents for 160-DN2
Page 1: ...User Manual DeviceNet Communication Module Catalog Number 160 DN2 Firmware 3 xxx...
Page 8: ...iv Table of Contents Publication 0160 5 18 June 2003...
Page 80: ...Publication 0160 5 18 June 2003 7 6 Troubleshooting Notes...
Page 82: ...Publication 0160 5 18 June 2003 A 2 Specifications Notes...
Page 115: ......