Rockwell Automation Publication 1440-UM001D-EN-P - September 2016
79
Configure the XM-124 Standard Dynamic Measurement Module
Chapter 2
Band Pass Filter Options
The Band Pass Filter options apply to the Band Pass Filter measurement mode
and affect the Band Pass Filter measurement.
Thrust Position Measurement Options
The Thrust Position measurement options apply to the Thrust Position
measurement mode and affect the Thrust Position measurement.
In this field
Values are
Comments
Min Frequency
25…1000 Hz
The high pass corner frequency or low cutoff frequency of the band pass filter.
Max Frequency
100…5500 Hz
The low pass corner frequency or high cutoff frequency of the band pass filter.
Table 13 - Thrust position parameters
Parameter Name
Values are
Comments
Output data unit
Select mil or μm.
The units of the Thrust Position measurement value.
Target Angle
Sets the angle between the shaft and the target surface. The target
surface moves with the shaft. The transducer is mounted perpendicular
to the target surface.
degrees
Upscale
Sets the movement of the target relative to the transducer that is
considered positive displacement.
Options:
• Away
• Towards
Calibration Offset (XM Serial Configuration
Utility only)
Enter the position of the current Transducer DC Bias reading.