Mount the Module
The XM-124 standard dynamic measurement module (catalog number
1440-SDM02-01RA) is used only with the 1440-TB-A/C terminal base.
1. Verify the keyswitch (D) on the terminal base unit (E) is at position 1 as
required for the module.
2. Verify the side connector (B) is pushed all the way to the left.
3. Make sure that the pins on the bottom of the module are straight so they
align properly with the connector in the terminal base unit.
4. Position the module (A) with its alignment bar (G) aligned with the
groove (F) on the terminal base.
5. Press firmly and evenly to seat the module in the terminal base unit.
The module is seated when the latching mechanism (C) is locked into
the module.
WARNING:
If you insert or remove the module while backplane
power is on, an electric arc can occur. This arc could cause an
explosion in hazardous location installations. Be sure that power is
removed or the area is nonhazardous before proceeding.
WARNING:
If you connect or disconnect wiring while the field-side
power is on, an electric arc can occur. This arc could cause an
explosion in hazardous location installations. Be sure that power is
removed or the area is nonhazardous before proceeding.
IMPORTANT
See XM Power Supply Solutions Application Technique, publication
ICM-
AP005
, for guidance in architecting power supplies for XM systems.
IMPORTANT
You cannot install the module unless the connector is fully extended.
C
E
D
B
F
31886
G
A
DYNAMIC MEASUREMENT
1440-DYN02-01RJ
Summary of Contents for 1440-SDM02-01RA
Page 8: ...8 Rockwell Automation Publication 1440 UM001D EN P September 2016 Table of Contents Notes...
Page 10: ...10 Rockwell Automation Publication 1440 UM001D EN P September 2016 Summary of Changes Notes...
Page 12: ...12 Rockwell Automation Publication 1440 UM001D EN P September 2016 Preface Notes...
Page 167: ......