The Electronic IF-171 Door Handle
Activating the permanently open mode
If you hold the credential that is equipped with the permanently open function in front of the read unit
for more than three seconds, the door is switched to the "permanently open" status. Thereafter, the
door can be opened without making another booking.
Signaling:
Credential with standard function and permanently open function:
GREEN --- GREEN --- Long GREEN
Signaling for a credential that only has the permanently open function:
Long GREEN
Booking memory entry:
Door permanently open
.
Deactivating the permanently open mode
Hold the credential at the read unit of the permanently open door for more than three seconds.
This deactivates the permanently open mode.
Signaling:
Credential with standard function and permanently open function:
GREEN --- GREEN --- long RED
Signaling for a credential that only has the permanently open function:
Long RED
Booking memory entry:
Toggle closed
In the case of credentials that are equipped
only
with the permanently open function, the
activation/deactivation occurs immediately after the door fitting has read the credential.
2.5 Maintenance and Cleaning
See also
Perform Time Synchronization ............................................................................................... 14
2.5.1 Replace Battery
Danger of injury caused by improper use
Do not charge, open or heat the batteries.
Always replace discharged batteries with new batteries.
Pay attention to the correct polarity when inserting the batteries.
Change the battery only with the door open. As long as the battery is removed, the door handle cannot
engage and thus cannot open the door.