Steam generator for
Steam bath/Hammam
Installation and User Manual
v2.1
1. Warnings
3
General warnings
Page 1: ...Steam generator for Steam bath Hammam Installation and User Manual v2 1 1 Warnings 3 General warnings 3...
Page 2: ...Steam pipe and steam outlet 11 Water discharge 12 Electrical connections 13 Control panel 14 Temperature sensor 16 Drain function 17 Remote start 18 Master Slave configuration 19 Low Level menu 20 5 U...
Page 3: ...ance of any kind There are parts in this product that are live or that could cause burns Maintenance and service of such a product should only be performed by specialized or qualified personnel This p...
Page 4: ...t Temperature probe with holder Water supply hose Water drain hose Steam line Control panel extension cable 2 meters Stainless steel flush mounted box for control panel Installation and User Manual Op...
Page 5: ...steam generator is operated by means of a touch panel which can be installed both inside and outside the steam cabin The control system measures the ambient temperature and regulates the production o...
Page 6: ...tion Important Before installing the system it is important to check whether the connections of the piping comply with the regulations The water inlet water outlet and steam outlet must be properly in...
Page 7: ...ve is fully open when the generator is on Only close the valve if the generator will not be active for a long period of time The piping used for the discharge of the steam generator must be able to wi...
Page 8: ...8 Mechanical installation The steam generator is designed for three types of installations as shown below On the wall On a shelf In a niche...
Page 9: ...9 Connections Preparation for making the mounting holes Drill holes in the wall to install the generator mounting bolts Make sure the holes are properly positioned in the wall...
Page 10: ...wall Warning Use screws each capable of lifting more than 50 kg Make sure generator is parallel to the wall Removing the housing Remove the screws as shown in the illustration below Remove the housin...
Page 11: ...d a total length of 6 meters The pipe must be insulated and able to withstand a temperature above 100 C The steam outlet must be installed at least 200 mm but not higher than 350 mm above the floor Th...
Page 12: ...12 Water drainage Without narrowed sections barriers or valves Minimum slope 4 Heat resistant material 100 C Siphon...
Page 13: ...Steam 3 2800 230 1 x 16 Alivida Steam 6 5600 1 x 230 cooking group 2 x 16 Alivida Steam 9 8400 1 x 230 cooking group 1 x 230 2 x 16 1 x 16 Alivida Steam 12 11200 2 x 230 cooking group 2 x 16 2 x 16 P...
Page 14: ...14 Control panel Mechanical installation The control panel can be installed on both the inside and outside of the steam bath A special stainless steel flush mounted box is used...
Page 15: ...15 Display dimensions Electrical installation Plug the male connector of the control panel into the corresponding female connector of the steam generator...
Page 16: ...erature sensor is held in place by a cylindrical holder which is installed on the inside of the steam room at a height of 160 cm Use silicone caulk to mount the holder in place Stelschroef voor hetvas...
Page 17: ...at the beginning only when the level sensor detects water and at the end of the steam session At the end of the steam session there is a 20 minute cool down cycle During the first 5 minutes of the co...
Page 18: ...e with a home automation system A connection between pin 1 and pin 2 of the M9 connector AUX IN ensures that the steam generator is switched on in its last setting for example 30 min 45 degrees Pay at...