Alinea EMPIRE II-2 Assembly And Instructions Download Page 1

TABLE ÉLECTRIQUE

Modèle: L’Empire II-2 (SH-LTM-2L-27.5-xx-2M-2)

Guide d`installation et d`instructions

ELECTRIC TABLE

Model: The Empire 

II-2 (SH-LTM-2L-27.5-xx-2M-2)

Assembly and instructions

* Image pour références seulement. / Images for references only.  

Summary of Contents for EMPIRE II-2

Page 1: ...L Empire II 2 SH LTM 2L 27 5 xx 2M 2 Guide d installation et d instructions ELECTRIC TABLE Model The Empire II 2 SH LTM 2L 27 5 xx 2M 2 Assembly and instructions Image pour r f rences seulement Image...

Page 2: ...lacer aucun objet de plus de 457mm 18 de hauteur en dessous de la table Ne pas ouvrir les composantes lectriques de ce produit Il y a un risque de chocs lectriques Ce produit est fabriqu avec un cycle...

Page 3: ...sion cables 1x Composantes incluses Parts Included Structure Frame Quincaillerie Hardware Composantes lectriques Electrical components S v p notez que B E sont pr assembl s Please note that B E are pr...

Page 4: ...sont pr assembl es Vous devez les ajuster approximativement selon la longueur de votre table Ne serrer pas compl tement les vis en pr vision de votre ajustement final Part B and E are preassembled Yo...

Page 5: ...p for both sides 8x 8x d tape Step 4 R aliser cette tape pour les deux c t s Assurez que l embout le plus long de d est du m me c t que l embout le plus long de a Complete this step for both sides Mak...

Page 6: ...de dessus de table d un minimum de 25 4 mm 1 mais ce n est pas requis Map out the desired position of the legs For maximum stability center the legs on the table Adjustable width of 1100 mm to 1600 mm...

Page 7: ...he control switch so that it does not exceed the table top Follow the steps on the next page to connect the electric components and attach the control box to the table top with the remaining screws Po...

Page 8: ...hements relever la table avec l aide d une deuxi me personne Connect the power cords as shown above Attach the cables using the cable clips to secure When all the connections are done ask a second per...

Page 9: ...set press and hold UP button lifting column will rise release to stop 4 After reset press and hold DOWN button lifting column will lower release to Stop Setting Memory Positions After pressing and hol...

Page 10: ...onous protection E06 Lifting columns are at different heights more than 10mm reset required 4 Overload protection E07 Desk load in excess of 140kg user needs to reduce load then reset or just need to...

Page 11: ...n to change it to Press Button M to preserve Inch display and pls wait for 2 seconds it will display current height Inch e Setting Handset display brightness 2br 1 Keep pressing Button M for 3 seconds...

Page 12: ...sensitivity level L5 We have 9 levels of upward sensitivity from L1 to L9 L1 is the most sensitivity L9 is the least sensitivity L5 is our factory setting upward sensitivity 3 Press button Up Down to...

Page 13: ...ton M to enter this will display you also can press button Up Down so that it will display and Mean to set the lowest position display height Mean to set a new lowest position Mean to set a new highes...

Page 14: ...current height l Adjust time reminder 9St 1 Keep pressing Button M for 3 seconds Handset will display S then release pressing Button M and press Button M again to enter the code 1Un will then appear 2...

Page 15: ...Un will then appear 2 Press button Up Down to be 12d Then press button M to enter It will appear Press 5 times button 1 continuously you can enter into fatigue mode selecting menu There will be 5 mode...

Page 16: ...uces ou centim tres au lieu de ASF Il est tr s important que la table puisse rejoindre LA POSITION MINIMUM plus basse sans obstruction ou arr t durant la proc dure et durant l op ration normale Si non...

Page 17: ...owest level stop and rise until reaching default height the readout will now show height in inches cm normally 24 0 instead of ASF LOWEST LEVEL POSITION MUST BE REACHABLE Path must be clear of obstruc...