show power-inline interface detail
Overview
This command displays detailed information for one or more Power over Ethernet
(PoE) ports.
For information on filtering and saving command output, see the
with AlliedWare Plus” Feature Overview and Configuration Guide
Syntax
show power-inline interface [<
port-list
>] detail
Mode
User Exec and Privileged Exec
Usage
The power allocated to each port is listed in the
Power allocated
row, and is
limited by the maximum power per Powered Device (PD) class, or a user
configured power limit.
Examples
To display detailed PoE port specific information for the port range 1.0.1 to 1.0.3,
use the command:
awplus#
show power-inline interface port1.0.1-1.0.3 detail
Output
Figure 18-5:
Example output from the
show power-inline interface detail
command
Parameter
Description
<
port-list
>
Enter the PoE port(s) to display information about only the specified
port or ports.
awplus#show power-inline interface port1.0.1-1.0.2 detail
Interface port1.0.1
Powered device type: Desk Phone #1
PoE admin enabled
Priority Low
Detection status: Powered
Current power consumption: 4800 mW
Powered device class: 1
Power allocated: 5000 mW (from configuration)
Detection of legacy devices is disabled
Powered pairs: Data
Interface port1.0.2
Powered device type: Access Point #3
PoE admin enabled
Priority High
Detection status: Powered
Current power consumption: 6720 mW
Powered device class: 2
Power allocated: 7000 mW (from powered device class)
Detection of legacy devices is enabled
Powered pairs: Data