Important Safety Information
The 8128 Strobe is
NOT INTENDED FOR FIRE ALARM
SIGNALLING APPLICATIONS.
The 8128 Strobe is intended for informative signaling in conjunction
with unified communication systems. The 8128 Strobe is suitable for
OSHA and ADA compliance when properly located and configured.
DO NOT LOOK DIRECTLY
at the 8128 Strobe while operating
in close proximity as vision may be affected.
The LEDs in the 8128
Strobe are classified according to the IEC 62471-2006 standard as
"RG-2" for risk group 2. This is defined as "
Moderate risk. Does not
pose a hazard due to aversion response to bright light or thermal
discomfort
".
PHOTO-SENSITIVITY
in some people with epilepsy can trigger
seizures from flashing or flickering lights. It is possible that some flash
patterns of the 8128 Strobe could trigger a seizure for some individuals
under some conditions. High intensity patterns should only be selected if
necessary for the 8128 Strobe to be effective.
Wet or Outdoor Environments
The 8128 LED Strobe is intended for indoor or outdoor locations and
may be subjected to spray or weather provided the rear wiring cavity
is properly sealed to prevent water ingress.
Gaskets included with the 8128 LED Strobe may be effective against
water ingress on some, but not all surfaces in which case additional
protective measures must be taken such as a perimeter sealant.
CAT5 or CAT6 connection wiring to an IEEE 802.3af compliant
network PoE switch must not leave the building perimeter
without adequate lightning protection.
Relay input and output connections must not leave the building
perimeter without adequate lightning protection.