15 

10.3. 1.

 

ON/OFF Menu  

The ON/OFF menu enables the user to turn the appliance on or off by swiping the finger over the field (shown below), 

while displaying the current appliance operating mode.  

 

 

10.3. 2.

 

Sett ings Menu  

The Settings menu shows the system variables that are necessary for its operation. The user can set the power by 

selecting from the list of values from P1 to P5 or automatic setting, and set the maximum boiler temperature in the range of 
40 ÷ 80°C. 

We do not recommend setting the water temperature below 57ºC due to possible condensation of the boiler, nor over 

75ºC

 

 

10.3. 3.

 

Power  

Menu for system combustion power setting in manual or automatic mode. In manual mode, the user can set the pellet 

combustion power. 

Power  

Description  

1-5(combustion power 1, 2, 3, 4, 5) 

Power is set manually by choosing Power 1, 2, 3, 4 or 5 

Auto  

Power is set automatically by the system 

 

10.3. 3.1.

 

Thermos tats  

The menu that allows you to set the so-called set boiler water temperatures (Boiler Thermostat). The adjustable boiler 

water  temperature  range  is  from  40°C  to  80°C.  By  setting  the  temperature  of  the  water  in  the  boiler,  the  user  sets  the 
operating condition of the boiler, i.e. the boiler will work at the set power until  it reaches the set water temperature in the 
boiler. When the set value of water temperature in the boiler is reached, the boiler enters the modulation state, i.e. continues 
to operate at minimum power. 
 

10.3. 4.

 

Cust omi zat ion Menu  

Customization menu includes an overview of the control panel variables and accesses the system menu reserved for 

service technicians and technical staff and is accessible by entering a 4-digit code. 

 

 

10.3. 4.1.

 

Sett ings  

There are several submenus within the setting icon. 
Time and Date – This option allows you to set the day, month, year and hour. 
Language – This menu allows you to change the language and offers 24 languages. 
Remote Control – This option allows control via a room thermostat (SYTX4 or 2WAYS2). It must be activated beforehand 

by setting a specific parameter. Remote control is not provided at the factory (OFF). 

Summer-Winter – The functionality of the boiler is modified depending on the season. 

Summary of Contents for Grande 37 Lux

Page 1: ...37 Lux Instruction for use maintenance and installation This product meets the requirements of the Ecodesign Directive in terms of efficiency and air pollution level in order to contribute to the red...

Page 2: ...by a person authorized by Alfa Plam The flame that develops in the boiler during normal combustion of wood biomass releases just the amount of carbon dioxide CO2 that would be released by natural wood...

Page 3: ...CE 10 8 IMPORTANT SAFETY INFORMATION 11 9 PELLET QUALITY IS VERY IMPORTANT 11 9 1 PELLET STORAGE 11 10 BOILER CONTROL SYSTEM 11 10 1 Electrical connection diagram 12 10 2 Touch screen control panel di...

Page 4: ...ents and or damage occurred due to use of non original or inappropriate spare parts Installations is solely within the responsibility of the installer 2 1 MAIN USER RESPONSIBILITIES The boiler user mu...

Page 5: ...ommissioning inspect the operation during at least 30 minutes in order to check whether all requirements have been met After finishing the installation the installer should provide the customer with t...

Page 6: ...the 80 mm flue pipe Therefore make sure that the flue pipe is completely sealed Carefully analyze the position and condition of the space through which the flue passes If the flue pipe passes through...

Page 7: ...ent always turned upward Figure 4 We recommend not making long horizontal sections for the flue connection If there is no other possibility the flue pipes should not have a downward slope but upward t...

Page 8: ...7 AISI 316 steel flue with double insulated chamber material resistant to 400 C Optimal efficiency 100 Waterproof flue with double insulated chamber and outer casing of light concrete Optimal efficien...

Page 9: ...ng devices such as a hoods hair dryers fans etc located in the room with the boiler combustion air fresh air must be supplied from outside In any case this should be discussed with the competent chimn...

Page 10: ...e universal ones Check if the valve is easily opened check with a finger so that it could be opened with the pump s power The non return valve is placed behind each pump If there are multiple pumps yo...

Page 11: ...nting damage due to sudden failure of a component which may seriously endanger the safety of persons and or your property Clean the firebox and the space underneath it when cleaning the ashes 6 2 SAFE...

Page 12: ...to the following safety rules Turn the pellet boiler off before beginning any procedure Make sure that the ash is cold before beginning any procedure on the boiler Vacuum the ashes deposited in the c...

Page 13: ...ONS ENSURE THE MAXIMUM OUTPUT OF THE BOILER AND THE TEMPERATURE OF THE SYSTEM Make sure that the pellet boiler and ashes are cold For complete weekly cleaning or after 200 kg of used pellets whichever...

Page 14: ...he type and quality of the pellets The manufacturer is not in any way responsible for poor performance of the boiler due to the use of poor quality pellets If sawdust or small decomposed pellets are p...

Page 15: ...isplay 1 2 Start screen display 2 2 YELLOW GREEN POWER CABLE FLUE GAS FAN TURBULATOR REDUCER PRIMARY AIR FAN LIGTER AUGER REDUCER THERMOMETER MANOMETER PENDULUM REDUCER PUMP MICRO SWITCH 1 MICRO SWITC...

Page 16: ...Auger Auger on off Pump Pump on off Valve Pendulum reducer on off V2 Room fan on off V3 Turbulator reducer on off A1 Heater igniter on off A3 Pendulum reducer on off A5 Auger reducer blocked not bloc...

Page 17: ...ition failure Er15 Power outage longer than 50 minutes Er16 Communication error RS485 Er17 Airflow regulator error Er18 No pellet Er25 Firebox cleaning motor error Er26 Turbulator cleaning motor error...

Page 18: ...es Boiler Thermostat The adjustable boiler water temperature range is from 40 C to 80 C By setting the temperature of the water in the boiler the user sets the operating condition of the boiler i e th...

Page 19: ...the steps decreases and increases the calibrated auger speed Fan Calibration menu for changing the speed of the flue gas fan The system has 15 calibration steps from 7 to 7 the factory setting is 0 Th...

Page 20: ...s is performed during the check up phase During this phase the flue gases motor is working at maximum speed while the auger and the igniter are turned off The check up phase takes a few seconds and th...

Page 21: ...ases temperature exceeds 230 C or when the boiler water temperature reaches 85 C During this phase the pellet feed stops until the flue gases temperature is below 230 C or the water temperature in the...

Page 22: ...ck error Internal clock problems Turn the appliance off and then on in the ON OFF menu Check the accuracy of the set time Insufficient internal battery capacity Check the accuracy of the chrono mode p...

Page 23: ...t and cleanliness Contact the service NOTE If the recommended solution fails to remove the direct cause of the alarm CONTACT ALFA PLAM CALL CENTER or the closest authorized service 11 INFORMATION ON B...

Page 24: ...8 Flue gas temperature value at reduced power C 70 Mean NOx value at 10 O2 at rated power mg m3 191 Mean CO value at 10 O2 at rated power mg m3 26 Mean dust emission value at 10 O2 at rated power mg m...

Page 25: ...d floor heating Note If only floor heating is connected to the boiler make sure to install an accumulation tank BUFFER Legend 1 Pellet boiler 2 Air vent 3 Safety valve 3 bar 4 Three way mixing valve w...

Page 26: ...draulic installation diagram accumulation tank Legend 1 Pellet boiler 2 Air vent 3 Safety valve 3 bar 4 Air vent 5 Circulation pump 6 Three way mixing valve with pipe thermostat 7 Accumulation tank BU...

Reviews: