Page 1: ...IM TE91A744 EN1 Toftejorg SaniMagnum with ATEX Certification in accordance with Directive 94 9 EC Instruction Manual Return to menu...

Page 2: ...jorg SaniMagnum 6 Performance Data for Toftejorg SaniMagnum 7 Installation and Normal Operation 8 General Installation Instructions 8 Special Conditions for Safe Use in accordance with the ATEX Certif...

Page 3: ...Return to menu...

Page 4: ...ions page 9 10 and take all necessary precautions according to your application and local regulations Note The illustrations and specifications contained in this manual were effective at the date of p...

Page 5: ...olymer materials No open thread or screws in the product areas The cleaning device is lubricated by the cleaning media No oil grease or other lubricants are used The Toftejorg SaniMagnum is designed f...

Page 6: ...ibrating impact and cascading flow that covers all internal surfaces of the tank or reactor The device s self cleaning feature is achieved by directing the cleaning media through the rotating bearing...

Page 7: ...1 4401 316 PTFE FDA approved 21 CFR 177 1550 head 1 4404 316L Lubricant Self lubricating with the cleaning fluid Connections 1 BSP or NPT thread Clip on or weld on for pipe ISO2037 ASTM A270 BS4825 p...

Page 8: ...immediately before the machine inlet In order to achieve the performance indicated in the curves the pressure drop in the supply lines between pump and machine must be taken in consideration Instruct...

Page 9: ...y lines and valves must be thoroughly flushed to remove remains of welding electrodes grinding dust scale and other foreign matter During handling and installation handle the machine with care in orde...

Page 10: ...C with an ambient temperature range of 0 C to 140 C Warning The maximum permitted process fluid pressure is 3 bar Warning The unit must not be operated in a vessel having an enclosed volume of greate...

Page 11: ...and tank must not exceed 20 000 The intended installation with standard clamp connections will ensure this In addition connecting pipe work must be electrically conductive and earthed to the tank stru...

Page 12: ...temperature must not exceed the maximum surface temperature according to the temperature class for the combustible gas or liquid Pressure Please make sure that the connections are correctly mounted be...

Page 13: ...s which you will find at the back of this manual How to contact Alfa Laval Tank Equipment A S For further information please feel free to contact Alfa Laval Tank Equipment A S Baldershoej 19 P O Box 1...

Page 14: ...line flushed before installation of tank cleaner Yes No Working hours before failure hours Cleaning Programme Cleaning media and conc Temperature Time Recirculation Is sterilising being used Yes No Pr...

Page 15: ...____________ Crystallising Soft particles size ______________________________ Has filter been installed in inlet line Yes Mesh size mm No Is tank cleaner flushed with clean water after tank cleaning Y...

Page 16: ...EU Declaration of Conformity Instruction Manual Toftejorg SaniMagnum with ATEX certification Page 15 in accordance with Directive 94 9 EC IM TE91A744 EN1 Return to menu...

Reviews: