7.2.4
Starting power too high
Possible cause
Action
Motor failure.
Repair the motor.
50 Hz pulley running on 60 Hz power
supply.
After immediate stop, install correct pulley.
Height position of paring disc incorrect.
Check and adjust.
Bearing damaged or worn.
Install new bearings.