7
Tighten the four bolts (1), (2), (3), (4) evenly
until dimension
A
has been reached.
When a pneumatic tightening device is used,
see table below for maximum torque.
Measure dimension
A
during tightening.
Bolt size
Bolt with bearing
box
Bolt with washer
Nm
kpm
Nm
kpm
M16
90
9.0
135
13.5
M20
175
17.5
265
26.5
M30
585
58
900
90
M39
1300
130
2000
200
For manual tightening, the tightening torque
has to be estimated.
If dimension
A
cannot be reached:
• Check the number of plates and the
dimension
A
.
• Check that all the nuts and bearing boxes
are running freely. If not, clean and
lubricate, or replace.
A
3
1
4
2
8
Mount the remaining locking bolts and check
measurement
A
on both sides, top and
bottom.
9
Mount protection sheets (if provided).
10
Connect pipes.
11
If the heat exchanger does not seal when
measurement A has been reached, it can be
tightened further to
A
minus 1.0%.
6.6 Pressure test after maintenance
Neither of these processes are allowed unless performed by a person
authorized according to local laws and regulations and following applicable
standards. If no such person is internally available, a third party authorized
200000423-1-EN-GB
41
Maintenance 6
EN
Summary of Contents for M line TS6
Page 6: ...7 Storage of the heat exchanger 45 7 1 Storage in packing box 45 7 2 Taken out of service 46 ...
Page 10: ...200000423 1 EN GB 10 2 Safety EN Safety ...
Page 18: ...200000423 1 EN GB 18 3 Description EN ...
Page 28: ...200000423 1 EN GB 28 5 Operation EN ...