1
Brush with cleaning agent.
2
Rinse immediately with water.
NOTE
Long exposure to the cleaning agents
can damage the gasket glue.
6.5 Closing
Follow the instructions below to ensure that the heat exchanger will be properly closed.
For bolt identification, refer to
1
Check that the hanger device is not
damaged.
2
Brush the threads of the bolts clean, using a
steel wire brush or the Alfa Laval thread
cleaner. Lubricate the threads with a thin
layer of grease, e.g. Gleitmo 800 or its
equivalent.
3
Attach the gaskets to the plates or check that
all gaskets are properly attached. Check that
all gaskets are correctly positioned in the
grooves.
NOTE
If the gasket is wrongly positioned, it will
show by the fact that it rises out of the
gasket groove or that it is positioned
outside the groove.
200000423-1-EN-GB
39
Maintenance 6
EN
Summary of Contents for M line TS6