11
CAUTION
To avoid hand injuries owing to sharp
edges, protective gloves should always
be worn when handling plates and
protection sheets.
Open the plate pack by letting the pressure
plate glide on the carrying bar.
If plates are to be numbered, do this before
removing the plates.
Plates need not be removed if cleaning is
done using only water, i.e. without a cleaning
agent.
WARNING
The plate pack may still contain a small
residual amount of liquid after draining.
Depending on the type of product and
type of installation, special arrangements,
e.g. drainage box, may be necessary to
avoid injury to personnel and damage to
equipment.
6.4 Manual cleaning of opened units
CAUTION
Never use hydrochloric acid with stainless steel plates. Water of more
than 330 ppm Cl may not be used in the preparation of cleaning solutions.
It is very important that aluminium carrying bars and support columns are
protected against chemicals.
NOTE
Be careful not to damage the gasket during manual cleaning.
200000423-1-EN-GB
37
Maintenance 6
EN