Page 18
Instruction Manual, Gunclean Toftejorg T-82
Standard machines and machines delivered with ATEX certification
in accordance with Directive 94/9/EC
IM-TE91A052-EN4
Installation and Normal Operation
(continued)
Normal Operation
Cleaning
Media:Use only media compatible with stainless steel, elastomer, polymer and carbon.
Please note that some of the polymer parts are in PEEK, which is not resistant to concentrated sulfuric
acid. Normal detergents, moderate solutions of acids and chemicals at elevated temperatures, as well
as hypochlorids should be avoided. If you are in doubt, contact your local Alfa Laval Tank Equipment
sales office.
After Use Cleaning:
After use flush the machine with fresh water. Cleaning solutions should never be
allowed to dry or set-up in the system due to possible "salting out" or "scaling" of the cleaning
ingredient. If cleaning media contains volatile chloride solvents, it is recommended
not to flush with
water after use, in case this can create hydrochloric acid.
Pressure:
Avoid Hydraulic shocks. Put on pressure gradually. Do not exceed 12 bar inlet pressure.
Recommended inlet pressure appears from Technical Data (page 8-13). High pressure in combination
with high flow rate will increase consumption of wear parts.
ATEX
Warning:
If stream cleaning is done through the machine, the steam pressure must not cause
the machine to rotate.
ATEX
Warning:
If the machine is drained using compressed air, then the compressed air pressure
must not cause the machine to rotate.