4.4 Flushing seal arrangement and pre-start up checks
1
A flushed seal arrangement may be fitted in
order to cool, heat or clean the seal area
(dependant on application). It is important
that:
• The flush is correctly connected (see
diagram).
• A compatible flushing fluid is used and
supplied at the correct pressure and flow
rate (see Flush Pressure and Flow Rates
section below)
• The flush is turned on at the same time/
prior to starting the pump and turned off at
the same time/after stopping the pump.
A Flush inlet
B Flush outlet
C Link pipe
A
B
3206-0015
C
2
Connecting the flush.
The following
equipment is strongly recommended when
using a flushing system:
• Control valve and pressure gauge, to
enable the correct flushing pressure to be
obtained and monitored.
• Isolation valve and check valve, so that
the flush can be turned off, and to stop any
unwanted substances flowing in the wrong
direction.
• A method of visibly indicating flushing fluid
flow.
Flush Connection Size (Femail)
Model
Size
BSP(G) / NPT w/Adapter
32/33/34
1/8"
42/43
1/8"
52/53/54
1/4"
62/63
1/4"
72/73/74
1/4"
200002348-1-EN-GB
21
Installation 4
EN