![Alfa Laval AquaMicro Installation And Service Instruction Download Page 49](http://html1.mh-extra.com/html/alfa-laval/aquamicro/aquamicro_installation-and-service-instruction_2894931049.webp)
Alfa Laval Micro
Installation and service instruction
49
14
Service instructions
Always start with the general service instruction before the specific instructions for each model.
To avoid the risk of scalding, make sure that no-one draws any water while servicing the
substation.
NOTE!
Make sure that the substation had been correctly installed.
This chapter has service instructions for:
Tap water temperature too low
Tap water temperature too high
Hot water temperature unstable or too low
Heating system temperature too high or too low
No heating
Noise in the radiator system
Heating temperature unstable
General service instructions
14.1
A. Tap water temperature too low
Reason
Action
A1)
Primary heating supply too low
Check the primary inlet temperatur
e
The temperature can be checked by means of the energy meter
(min 65º C) or contact the primary heating medium provider.
A2)
Handle on control valve
incorrectly positioned
Adjust the handle on the control valve
The hot water temperature can be controlled by turning the handle, on the
control valve for domestic hot water, anti-clockwise for increased tap
water temperature. To decreasing tap water temperature turn the handle
clockwise until the desired tap water temperature is reached (50ºC
approx.). The stabilisation time for the hot water temperature is about 20
seconds.
NOTE!
Alfa Laval recommends that the tap water temperature is set to
10º less than the primary inlet temperature. If a HTC the temperature
must be 15º less than the primary inlet temperature.
A3)
Filter for heating media clogged
Before starting out repairs always close the primary supply and
return shutoff valves and drain the system with the draining
valves.
After finishing repair; open the shutoff valves. Start with primary
supply and then the return lines, in order to avoid pollutions in
the system. Open up the valves slowly to avoid pressure
surges.
Check if the filter for heating
media is blocked
Release the filter holder and
remove the cartridge.
Clean the filter with water and
refit the cartridge. Screw the filter
holder with a momentum of 10-
20 Nm.
Picture 43
Summary of Contents for AquaMicro
Page 2: ......
Page 16: ...Alfa Laval Micro Installation and service instruction 16 Measure sketch 2 9...
Page 19: ...Alfa Laval Micro Installation and service instruction 19 Picture 12...
Page 45: ...Alfa Laval Micro Installation and service instruction 45 Micro STC and Micro STC2 Picture 36...
Page 60: ...Alfa Laval Micro Installation and service instruction 60 17 Declaration of conformity...