7
Installation
7.5
Gauges
Pressure gauges on both the suction and
the pressure side must be connected by 1/2”
sockets and ball valves.
7.6
Commissioning
7.6.1
Cleaning the pipe system
To protect the pump against soiling the complete
pipe system has to be cleaned carefully before
initial commissioning of the pump.
7.6.2
Filling the pump
The filling procedure must be followed when the
pump is taken into operation after installation
and whenever the pump casing has been
emptied of oil, for example, when the pump has
been dismantled.
!
WARN
ING
Entrapment hazard
Do not start filling the pump unless the power is
switched off.
1.
Remove the fan cover from the electric
motor.
2.
Turn the pump shaft or the fan impeller of
the motor. This tests that the pump runs
smoothly. If the pump cannot be turned by
hand, remedy the fault before installing the
pump, see
4.2 Troubleshooting on page 19
.
3.
Open the port on the suction pipe near the
pump.