![Alfa Laval ALP 100 Operating Instructions Manual Download Page 35](http://html1.mh-extra.com/html/alfa-laval/alp-100/alp-100_operating-instructions-manual_2895163035.webp)
8.4 Protect the pump against soiling
CAUTION
Damage through impurities in the pipe system
.
• During welding work attach protective covers to the connecting flanges.
• Ensure when welding that welding beads and abrasive dust cannot get into
the pipe system and the pump.
• After the connecting work carefully clean the pipe system; refer to
8.4.1 Connecting the pump to the pipe system
Figure 8: Wrong installation
Figure 9: Correct installation
CAUTION
Danger of damage to the device or impaired functionality through
mechanical stresses
.
• Ensure that the pump mounting on the pipe system is free of mechanical
stress.
200007725-1-EN-GB
35
Installation, removal and connection 8