![Alfa Laval Alfie Instruction Manual Download Page 57](http://html1.mh-extra.com/html/alfa-laval/alfie/alfie_instruction-manual_2895106057.webp)
10 Technical data
10.1 Technical data, system
Denomination:
Alfa Laval Alfie 500
Application:
Use is restricted to removal of
solids and oil from water-based
liquid with the following
specifications.
Process media:
Water-based liquid
Technical design
pH value:
6 – 9
Separation temperature:
+15 – +70 °C
Max. throughput:
500 litres/hour
(50/60 Hz)
Max. ambient temperature:
+45 °C
Counter pressure at outlet of
unit:
- Recommended
100 - 180 kPa
- Max.
185 kPa
Suction height:
Max. 1.7 metres
Volume in collecting tank:
20 litres
Power supply:
230 V (±5%), 1 phase, 50/60
Hz
100/110/120 V (±5%), 1 phase,
50/60 Hz (option, with fitted
transformer)
Amperage:
10 A (230 V), 16 A (100 – 120
V)
Sound:
Sound power:
Max. 8.9 Bel(A), ISO 3744
Sound pressure level:
Max. 75 dB(A), ISO 3744
Enclosure class:
IP 54
Weight, total:
60 kg (135 lbs)
Dimensions (LxHxW):
620 x 1140 x 510 mm (24” x
45” x 20”)
57
Summary of Contents for Alfie
Page 6: ......
Page 10: ...2 Application ...
Page 18: ...4 Description of main parts ...
Page 20: ...5 Working principle of the separator ...
Page 30: ...6 Control Cabinet ...
Page 47: ...9 Maintenance Dismantling G04491c1 See comments on opposite page 47 ...
Page 53: ...9 Maintenance G0449671 53 ...
Page 54: ...9 Maintenance G0449681 54 ...
Page 60: ...11 Lifting instruction ...
Page 61: ...12 Diagrams 12 1 Electrical system Alfa Laval ref 9014733 Rev 7 61 ...