![Alfa Laval 881176-09-01/1 Instruction Book Download Page 48](http://html1.mh-extra.com/html/alfa-laval/881176-09-01-1/881176-09-01-1_instruction-book_2895138048.webp)
6.4 Connection list
6 Technical references
48
6.4
Connection list
Alfa Laval ref. 576334, rev. 0
No.
Description
Requirements/limits
201
Inlet for process liquid
Allowed temperature
Min. 15 °C, max. +70 °C
Viscosity
Max. 40 cSt
Flowrate
Max. 525 litres/hour
Pressure
0-60 kPa
220
Outlet for light phase
No counter pressure
221
Outlet for heavy phase
Counter pressure
170 kPa
225
Bowl drain outlet
No counter pressure
701
Motor for separator
See
‘‘6.5 Interface description” on page 49
Voltage
3 x 230 VAC / 125 Hz
Current, max.
3 A
760
Cover interlocking switch
See
‘‘6.5 Interface description” on page 49
Type
Magnetic proximity switch
Switch rating, voltage
load
230 V AC
20 VA