Power Requirement
Current Draw
PIR Detector
PIR Sensitivity Adjustment
PIR Pulse Count
MW Detector
MW Detection Range
MW Pulse Count
Warm-up Period
Alarm Period
Alarm Display
PIR Detection Display
MW Detection Display
Relay Output
Tamper Contact
Operating Temperature
Environment Humidity
9.5 to 16VDC (Normal 12VDC)
35mA max.
Selectable (60 or 80 or 100 or 120%)
Selectable (2 or 4 pulses)
MIC Module (10.525GHz)
20ft to 66ft (6m to 20m)
2 pulses
Red LED monitor (ON/OFF selectable)
Green LED ON
Orange LED ON
2C Contact (N.C/N.O)
30VDC 0.35A max.
N.C dry contact 30VDC 0.5A max.
95% max.
2.76 (70)
1.73 (43.9)
6.3 (160)
inches ( mm )
ft(m)
TOP VIEW
SIDE VIEW
MW DETECTOR
PRINTED CIRCUIT BOARD
MW LED
MODE SWITCH
RELAY
PIR DETECTOR
TERMINAL
PIR LED
ALARM LED
MW RANGE
LOCKING SCREW
TAMPER SWITCH
120% 100% 80%
60%
1
2
3
4
5
PIR SENSITIVITY
ADJUSTMENT
PIR SENSITIVITY
ADJUSTMENT
DUAL MODE
(PIR & MW)
OFF
PIR MODE
(PIR only)
Do not install towards a
driveway and a place with much
traffic, etc.
Y ft ( X m)
Y:
6.6
〜
8.2 ft
X:
2.0
〜
2.5 m
Unit installed height should be
Y
ft (X
m) from floor so that the
full coverage could be achieved.
Do not limit a desired detection
zone by interference of car,
screen, potted plants, etc.
Mount the unit only on a solid
locatiom or surface.
Mounting hole
MW DETECTION AREA
640-43575
MW Range Adjustment
Volume Adjustment
3.29 (83.5)
ANIMAL Immune (80 lbs.)
OUTDOOR DUAL TECHNOLOGY DETECTOR
INSTALLATION INSTRUCTIONS
XC-1XT
1. SPECIFICATIONS
2. DETECTION PATTERN
3. DESCRIPTION
4. DIMENSIONS
5. MODE SWITCH
7. INSTALLATION HINTS
PIR PULSE COUNT 2
LED ON
4
We may change specification and design without prior notice as part of its
continuing program of product improvement.
Weight
6.3oz(180g)
50
±
15 sec
2
±
0.4 sec
−
4
゚
F to
+
122
゚
F (
−
20
℃
to
+
50
℃
)
6.3in.
×
2.76in.
×
1.73in.
(160mm
×
70mm
×
43.9mm)
Dimensions(H
×
W
×
D)
MIN
MAX
6. MW Range Adjustment
MW range adjustment is provided allowing
use in difficult environments.
MAX:Increases
MIN :Decreases
Dual-Element
PIR Detection Range
Standard (Animal immune) range lens
Long range lens (option)
ADJUSTMENT