Alemite 3572-A Service Manual Download Page 1

Alemite, LLC

167 Roweland Drive, Johnson City, Tennessee 37601

www.alemite.com

Copyright 

© 

2014 by Alemite, LLC

Service Guide

High Volume Control Valve

671059

          3572-A

          3572-B

SER 3572-A

Revision (8-14)

Description

CAUTION

Do not operate this valve with an antifreeze and water 
mixture. 

The control valve models included in the 3572 series are 

designed to dispense a variety of fluids. These include engine 
oils, diesel oils and hydraulic oils.

WARNING

Release all pressure within the system prior to 

performing any overhaul procedure. 

• Disconnect the air supply line from the pump 

motor. 

• Into an appropriate container, operate the control 

valve to discharge remaining pressure within the 
system.

Never point a control valve at any portion of your body 
or another person. Accidental discharge of pressure 
and/or material can result in personal injury.

Read each step of the instructions carefully. Make sure 
a proper understanding is achieved before proceeding.

Fluid Inlet (Swivel) 

3/4” NPTF (f)

Maximum Operating Pressure

1450 psi (100 bar)

Assembly

Apply thread Sealant to the male threads on the extension  

(1 or 2).

NOTE

: Do not apply thread sealant to the first two 

(2) threads. Contamination can occur.

Install the Extension into the Handle. Tighten securely.

Prime and Test

NOTE

: Perform the following procedures at an air 

pressure that allows the pump to begin to cycle. 
Regulate the amount of air to the pump with a 
pressure regulator.

 

Should valve leakage occur at anytime, refer to the 

Troubleshooting Chart.

  1. Point the control valve into an appropriate collection 

container.

  2. Allow the pump to deliver fluid to the control valve.

• The control valve should show no leakage nor dispense the 

fluid.

  3. Cycle the control valve Lever Assembly several times.

• Fluid should flow once air is eliminated from the control 

valve (and system). 

With the Lever in the released position, no fluid should 

appear at the Nozzle.

 If product does appear, refer to the 

Troubleshooting Chart.

      The non-drip nozzle opens automatically when fluid is 
dispensed.

     After use, the nozzle should be manually pushed closed to 
prevent oil drip.

Figure 1

 

High Volume Control Valve Model 3572-A  