14
11. SPECIFICATIONS
Indoor-unit:
Temperature:
measurement range:
-9.9°C ~ 50°C (‘L0’ or ‘HI’ when out of range)
resolution:
0.1°C
accuracy:
20°C - 24°C = ±1°C
0°C - 20°C en 24°C - 40°C = ±2°C
40°C - 50°C = ±3°C
humidity:
1% ~ 99% RH (if out of range, lower then the
display will show 1%, higher the display will
show 99%)
resolution:
1% RH
accuracy
:
40% - 80% = ±5%,
others = ±8%
air pressure:
800 ~ 1100hPa
resolution: 1hPa
measure time:
every hour
High correction:
-90meter ~ 1990meter
alarm duration:
180 seconds
snooze duration:
5 minutes
high/low alarm:
outdoor temperature:
low default 0°C (-50°C~10°C)
high default 35°C (28°C~70°C)
indoor temperature:
low default 20°C (0°C~23°C)
high default 28°C (26°C~50°C)
power supply:
3x 1,5V battery, format AAA
adapter:
Input voltage: 100-240VAC
Input frequency: 50/60Hz +/-3Hz
Output voltage constant: 5.0V
Output current constant: 0.3A
Output power constant: 1.5W
Efficiency 50% load: 69.86%
Input power no load: 0.08W
dimensions: 125(H)x190(W)x15(D)mm
Outdoor-unit wind:
Temperature:
measurement range:
-50°C ~ 70°C (‘L0’ or ‘HI’ when out of range)
resolution:
0.1°C
accuracy:
20°C - 24°C = ±1°C
0°C - 20°C en 24°C - 40°C = ±2°C
40°C - 50°C = ±3°C
humidity:
1% ~ 99% RH (if out of range, lower then the
display will show 1%, higher the display will
show 99%)
resolution:
1% RH
accuracy
:
40% - 80% = ±5%,
others = ±8%
wind speed:
0km/u ~ 127,5km/u
Resolution: 1km/u
power supply:
4x 1,5V battery, format AA (*)
dimensions: 382(H)x260(W)x105(D)mm
Outdoor-unit rain:
rainfall:
measurement range: 0-6000mm (‘---’ if outside this range)
accuracy:
+/-10%
resolution:
0,1mm upon precipitation <1000mm
1mm upon precipitation >1000mm
power supply:
2x 1,5V battery, format AA (*)
dimensions: 120(H)x164(W)x104(D)mm
Radio:
transmit frequency:
434,025 MHz
transmit interval:
wind (55sec.) rain (90sec.)
range:
30m.
RF power:
< 0 dBm