Page 2: ...s International Inc and are used under license Alcohol Countermeasure Systems is the trading style of Alcohol Countermeasure Systems Corp 2013 Alcohol Countermeasure Systems The information disclosed in this document is the valuable property of Alcohol Countermeasure Systems and all copyright and other proprietary rights to this document are reserved No reproduction of this document is permitted w...

Page 3: ...f the interlock system Test that all inputs to the L OEM handset are off and that buttons are working If the handset is awake hold buttons for 3 seconds The handset should go to the lower power state the display and all the LEDs should turn off To test the display backlights and left pushbutton wake the handset up by pressing the left pushbutton The display should show Alcolock Disabled OK to star...

Page 4: ...lace ECU Communication error Handset has lost communication with ECU 1 Check voltage of vehicle during ignition cranking Voltage should stay above 9V 2 Replace spiral cable 3 Replace ECU 4 Replace Handset Error code 30 Handset blow tube temperature is out of range 1 Replace handset Error code 50 Sampling pump piston within the fuel cell is stuck in the active position 1 Replace handset Handset vol...

Page 5: ...rd cylinder can be properly stored Transportation and storage of compressed gases in vehicles is dangerous and should be avoided Other precautions Never remove or alter canister labels Remove the valve and install the protective cap on cylinders when not in use Store cylinders in a cool well ventilated area away from sources of heat CYLINDER SETUP 1 Examine the canister and valve for any damage an...

Page 6: ...reases in increments of 200 meters Press the right button to Accept 9 A Wait message is displayed followed by a 2 00 minute warm up The handset is ready for calibration when the TURN ON GAS message is displayed 10 Insert the delivery tube from the regulator valve into the mouthpiece port Keep holding the handset as the delivery tube is rigid 11 Press the valve down to release the gas while keeping...

Page 7: ...The alcohol gas standard is expired A connection to or from the gas valve is not secured properly check all connections The value entered in Altitude menu is incorrect ALTITUDE REFERENCE GUIDE The altitude adjustment is in increments of 200 meters Choose the closest city elevation and round the altitude up or down to the closest value accordingly EXAMPLE CITY ALTITUDE M SETTING Amsterdam 0 0 Berli...